Abstract
The factors are discussed which determine the range of an optical communication system, such as: atmospheric transmission; source area, flux, brightness, modulation, and audio pass band; transmitter and receiver focal lengths, areas, and beam widths; and detector cell noise and area. Detector cell signal-to-noise ratio varies inversely as the square root of cell area in the ideal case. For non-image-forming systems, the Abbé sine condition is replaced by a useful rule of constancy of area times solid angle. A wide-angle system is a short-range system.
A general equation is given relating the range to these factors; it leads to a simple nomograph for estimating performance of a system. From laboratory measurements on components, the field range of a system may be predicted to an accuracy of mile if the atmospheric transmission is known.
© 1948 Optical Society of America
Full Article | PDF ArticleMore Like This
W. S. Huxford and John R. Platt
J. Opt. Soc. Am. 38(3) 253-268 (1948)
Max Herzberger
J. Opt. Soc. Am. 38(8) 736-738 (1948)
R. Clark Jones
J. Opt. Soc. Am. 38(8) 671-685 (1948)