Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Diode-pumped actively Q-switched Tm:YAP/BaWO4 intracavity Raman laser

Open Access Open Access

Abstract

We report an intracavity Raman laser based on BaWO4 Raman conversion in a diode-pumped actively Q-switched Tm:YAP laser for the first time. With an incident diode power of 17.5 W and a pulse repetition rate of 1 kHz, the maximum average output powers of 880 mW and 306 mW for the fundamental laser at 1.94 μm and the first Stokes laser at 2.36 μm were obtained, respectively. The pulse width and pulse energy of the first Stokes laser were 14.1 ns and 0.31 mJ, respectively. The Raman gain coefficient of the BaWO4 crystal was estimated to be 1.1 cm/GW at 1.94 μm.

© 2015 Optical Society of America

1. Introduction

Laser sources in the 2-3 μm region play an important role in many fields including high sensitivity chemical sensing, and environmental monitoring. Indeed, some important gas molecules exhibit strong absorption lines around the infrared (IR) spectrum, such as CH4 (2.35 μm), C2H4 (2.9 μm), NH3 (2.1 μm), HF (2.5 μm), CO (2.3 μm) and H2O (around 2.5 μm). Several technologies have been developed to obtain laser sources in the 2-3 μm region. GaSb-based diode lasers emitting at wavelengths above 2 μm have been reported [1,2]. Crystalline and fiber rare-earth doped lasers have been utilized for generating the tunable emission in the 2-3 μm region [3,4]. Nonlinear optical processes can also produce the IR radiation. For instance, optical parametric oscillators based on MgO-doped periodically poled LiNbO3 [5] and difference frequency generators based on GaAs [6] are efficient devices to generate the IR laser source. In addition, stimulated Raman scattering (SRS) in solid-state Raman material is a potential method to extend the spectral coverage of the present lasers, and playing a more and more important role in generating new laser lines [7,8]. The output wavelength of a Raman laser depends on Raman spectrum of the Raman crystal and the wavelength of the fundamental laser. The commonly known Raman crystals include Ba(NO3)2 [9,10], YVO4 [11,12], GdVO4 [13], diamond [14,15], and variety of tungstate crystals [16–22].

For Raman lasers based on tungstate crystals, Nd-doped lasers are primarily used as fundamental lasers. The Raman lasers based on tungstate crystals with more than 2 μm output wavelength were seldom reported in the last ten years. In 2002, Batay et al. observed the first Stokes component of Raman self-frequency conversion at 2365 nm for a Tm:KY(WO4)2 sample [23]. In 2013, we reported a diode-pumped actively Q-switched Tm,Ho:GdVO4/BaWO4 intracavity Raman laser at 2.53 μm [24]. As the fundamental laser, the Tm,Ho:GdVO4 laser operated at liquid Nitrogen temperature. With an incident pump power of 2.8 W, an average output power of 186 mW for the first Stokes laser of 2.53 μm was obtained at a pulse repetition rate (PRR) of 1 kHz.

In this paper, we report an intracavity Raman laser based on BaWO4 Raman conversion of a Q-switched Tm:YAP laser at room temperature. To the best of our knowledge, this is the first time BaWO4 Raman conversion in a diode-pumped actively Q-switched Tm:YAP laser has been demonstrated. With a pump power of 17.5 W, the maximum average output powers of 880 mW for the fundamental laser of 1.94 μm and 306 mW for the first Stokes laser of 2.36 μm were obtained at a PRR of 1 kHz, respectively. The total optical-to-optical conversion efficiency was 6.8%. The pulse width and single pulse energy of the first Stokes laser at 2.36 μm were approximately 14.1 ns and 0.31 mJ, respectively. The Raman gain coefficient of the BaWO4 crystal was also estimated to be 1.1 cm/GW at 1.94 μm.

2. Experimental setup

Figure 1 shows the experimental configuration of the intracavity Raman laser based on BaWO4 Raman conversion. The pump source is a 20 W fiber-coupled continuous-wave 794 nm diode laser with a 400 μm fiber core diameter and a numerical aperture of 0.22. A focus lens system with a pair of plane-convex lenses was used to focus the pump beam into the laser crystal. The pump spot diameter in the laser crystal was approximately 560 μm. The coupling efficiency of the focus lens system is 95%. The laser gain medium was an a-cut 3.0 at.% Tm:YAP crystal with dimensions of 3 mm × 3 mm × 10 mm. Both end faces of the laser crystal were antireflection coated for the fundamental laser wavelength at 1.94 μm and the pump wavelength at 794 nm. The laser crystal was wrapped in indium foil and held in a copper heat sink which was maintained at a temperature of 18 °C. The a-cut 4 mm × 4 mm × 20 mm BaWO4 crystal was used as Raman gain medium. Both end faces of the BaWO4 crystal were antireflection coated in the range of 1800–2550 nm (R<3%). The Raman laser was wrapped with indium foil and mounted on a water-cooled copper heat sink maintained at 19 °C. A water-cooled Brewster-cut acousto-optic modulator was used for Q-switched operation, and was driven at 27 MHz with 50 W RF power.

 figure: Fig. 1

Fig. 1 Configuration of the intracavity Raman laser based on BaWO4 Raman conversion of an actively Q-switched Tm:YAP laser

Download Full Size | PDF

The Raman laser comprised a fundamental laser cavity and a Raman laser cavity. For the fundamental laser, we used an L-shaped cavity composed of three mirrors (M1, M2 and M4). As the output coupler of the fundamental laser, the mirror M1 with a curvature radius of 300 mm was partial transmission at 1.94 μm (T = 4%). The 45° dichroic flat mirror M2 was antireflection coated at 794 nm (R<1%), and high reflectivity at 1.94 μm (R>99.8%). The curved mirror M4 with a curvature radius of 500 mm, shared by the Raman cavity as the output coupler of the Raman laser, was coated for high reflectivity at 1.94 μm (R>99.5%), and partial transmission at 2.36 μm (T = 10%). One surface of the flat intracavity mirror M3 was antireflection coated at 1.94 μm (R<1%), the other surface was antireflection coated at 1.94 μm (R<1%) and high reflectivity at 2.36 μm (R>99.5%). Mirrors M3 and M4 constituted the Raman laser cavity. The physical cavity lengths of the fundamental laser and the Raman laser were about 148 mm and 33 mm, respectively.

3. Experimental results and discussion

The spectral information of the Raman laser in Q-switched operation was monitored by a Zolix spectrograph (Omni-λ 300, resolution of the spectrum is 0.1 nm). The fundamental and Raman laser output powers were measured by a power meter (Coherent, PM30). The pulse temporal behaviors of the fundamental and Raman lasers were recorded by a 300 MHz bandwidth digital phosphor oscilloscope (Tektronix,TDS3032B) with a >100 MHz bandwidth IR detector (Vigo, PVM-10.6).

The operation of the Raman laser was investigated at a PRR of 1 kHz. The fundamental laser was measured to be linearly polarized, and its polarization was parallel to the c-axis of the BaWO4 crystal. Figure 2 shows the spectral information of the Raman laser, which was recorded at an incident pump power of 15.2 W. It can be seen that the fundamental laser emission was at 1.94 μm and the first Stokes component was at 2.36 μm. We can see that the frequency shift of the fundamental laser and the first Stokes component was 924 cm−1, which was in agreement with the Raman frequency shift of the a-cut BaWO4 crystal reported in [22,25]. In this experiment, the second Stokes component was not observed at the maximum Raman output power.

 figure: Fig. 2

Fig. 2 Optical spectrum for the Raman laser based on intracavity BaWO4 Raman conversion.

Download Full Size | PDF

Figure 3 shows the average output powers of the fundamental laser at 1.94 μm and the first Stokes laser at 2.36 μm as function of the incident pump power at 794 nm. As shown in Fig. 3, the fundamental and Raman output powers increased almost linearly with the incident pump power from 9.1 W to 17.5 W. The maximum average output powers of 880 mW at 1.94 μm and 306 mW at 2.36 μm were obtained at a pump power of 17.5 W, respectively. At the highest output power level, the power stabilities of the fundamental laser and the first Stokes laser were less than 1.2% and 1.6% in 30 minutes, respectively. With incident pump power further increasing, the coating of the cavity mirror M3 was damaged, which resulted in a sudden decrease of the output powers of the fundamental laser and the first Stokes laser. If quality of the mirror coating could be improved, the average output power of Raman laser would continue to grow.

 figure: Fig. 3

Fig. 3 Average output power at 1.94 and 2.36 μm as a function of incident pump power at a PRR of 1 kHz.

Download Full Size | PDF

The threshold powers of the fundamental laser and the Raman laser at a PRR of 1 kHz were 7.0 W and 9.1 W (see Fig. 3), respectively. Figure 4(a) shows the typical pulse shape of the fundamental laser at an incident pump power of 9 W. We can see that the pulse shape of the fundamental laser was almost symmetrical under the Raman threshold pump power. Figure 4(b) shows the typical pulse shapes for the Raman and fundamental lasers, which were recorded at an incident pump power of 15.2 W. Once the Raman laser pulse arose, the envelope of the fundamental laser pulse would change. The depletion of the fundamental laser pulse resulted in building up of the Raman laser pulse.

 figure: Fig. 4

Fig. 4 Typical oscilloscope traces of the Raman laser at a PRR of 1 kHz: (a) the pulse shape of the fundamental laser at an incident pump power of 9 W; (b) the pulse shapes for the Raman laser and fundamental laser at an incident pump power of 15.2 W.

Download Full Size | PDF

For efficient Raman conversion, the fundamental radiation intensity inside the Raman cavity must exceed certain threshold level. When the Raman medium is placed in a Raman cavity, the SRS threshold condition can be expressed as [26]

gIthL=25/Neff,
Where g is the Raman gain coefficient of the medium; Ith is the threshold intensity of the fundamental radiation in the Raman medium; L is the length of the Raman medium; Neff is the effective number of passes of Raman radiation through the Raman cavity, which can be expressed as
Neff(Lrτ0c+125ln1R)1,
Where Lr is the optical length of the Raman cavity; τ0 is the fundamental pulse duration; c is velocity of light; R is the product of the reflectivities of the Raman cavity mirrors for the Raman radiation.

When the fundamental output coupler M1 is used, the threshold intensity of the fundamental radiation for the generation of the first Stokes component in the BaWO4 crystal can be estimated. According to Eqs. (1) and (2), the Raman gain of the BaWO4 crystal at 1.94 μm could be estimated. For this experiment, the average fundamental output power was 240 mW for the threshold pump power of the Raman laser. The corresponding fundamental pulse duration τ0 was approximately 170 ns. By using ABCD matrix, the average diameter of the fundamental laser beam in the BaWO4 crystal was calculated to be approximately 260 μm. The fundamental intensity Ith was estimated to be 33 MW/cm2. The output coupler reflectance R for the first Stokes component at 2.36 μm was 90%. The optical length of the Raman cavity Lr was approximately 4.8 cm. The effective number of passes was calculated to be Neff ≈330. Therefore, the Raman gain coefficient of the BaWO4 crystal was approximately 1.1 cm/GW at 1.94 μm.

Figure 5 shows a stretched single pulse shape and a typical oscilloscope trace of the Raman laser pulse train at a pump power of 17.5 W, indicating the pulse duration of the first Stokes laser was approximately 14.1 ns. The corresponding single pulse energy and peak power were calculated to be 0.31 mJ and 22 kW, respectively. The Raman output beam profile was measured with a commercial beam analyzer (Electrophysics, MicronViewer 7290A) As shown in Fig. 6, the output beam was close to fundamental transverse electromagnetic mode (TEM00).

 figure: Fig. 5

Fig. 5 Oscilloscope trace of the Raman laser at an incident pump power of 17.5 W and a PRR of 1 kHz: (a) the stretched single pulse shape; (b) the Raman laser pulse train.

Download Full Size | PDF

 figure: Fig. 6

Fig. 6 The Raman laser output beam spatial profiles measured with a beam analyzer: (a) two dimensional distributions; (b) three dimensional distributions.

Download Full Size | PDF

4. Conclusions

In conclusion, the characteristics of the intracavity Raman laser based on BaWO4 Raman conversion in the diode-pumped actively Q-switched Tm:YAP laser has been demonstrated. With an incident pump power of 17.5 W, an average output power of 306 mW at the first Stokes wavelength of 2.36 μm was obtained at a PRR of 1 kHz, 880 mW at the fundamental wavelength of 1.94 μm was obtained at the same time. The pulse width and pulse energy of the first Stokes laser were approximately 14.1 ns and 0.31 mJ, respectively. It presents the potential for increasing the average output power of the Raman laser by optimizing cavity design and employing high-quality mirrors. The Raman gain coefficient of the a-cut BaWO4 crystal was estimated to be 1.1 cm/GW at 1.94 μm.

Acknowledgments

This research work was financially supported by the Natural Science Foundation of China (61378027, 61275138), and the Fundamental Research Funds for the Central Universities. This work was also supported by the 111 project (B13015), to the Harbin Engineering University. The authors thank Professor Huaijin Zhang (Key Laboratory of Crystal Material of Shandong University) for providing the BaWO4 sample.

References and links

1. Q. Gaimard, L. Cerutti, R. Teissier, and A. Vicet, “Distributed feedback GaSb based laser diodes with buried grating,” Appl. Phys. Lett. 104(16), 161111 (2014). [CrossRef]  

2. J.-M. Hopkins, A. J. Maclean, D. Burns, E. Riis, N. Schulz, M. Rattunde, C. Manz, K. Köhler, and J. Wagner, “Tunable, single-frequency, diode-pumped 2.3 μm VECSEL,” Opt. Express 15(13), 8212–8217 (2007). [CrossRef]   [PubMed]  

3. P. Koopmann, S. Lamrini, K. Scholle, M. Schäfer, P. Fuhrberg, and G. Huber, “Holmium-doped Lu2O3, Y2O3, and Sc2O3 for lasers above 2.1 μm,” Opt. Express 21(3), 3926–3931 (2013). [CrossRef]   [PubMed]  

4. E. A. Anashkina, A. V. Andrianov, M. Yu Koptev, S. V. Muravyev, and A. V. Kim, “Generating femtosecond optical pulses tunable from 2 to 3 μm with a silica-based all-fiber laser system,” Opt. Lett. 39(10), 2963–2966 (2014). [CrossRef]   [PubMed]  

5. Z. Jiao, G. He, J. Guo, and B. Wang, “High average power 2 μm generation using an intracavity PPMgLN optical parametric oscillator,” Opt. Lett. 37(1), 64–66 (2012). [CrossRef]   [PubMed]  

6. T. H. Stievater, R. Mahon, D. Park, W. S. Rabinovich, M. W. Pruessner, J. B. Khurgin, and C. J. K. Richardson, “Mid-infrared difference-frequency generation in suspended GaAs waveguides,” Opt. Lett. 39(4), 945–948 (2014). [CrossRef]   [PubMed]  

7. H. M. Pask, “The design and operation of solid-state Raman lasers,” Prog. Quantum Electron. 27(1), 3–56 (2003). [CrossRef]  

8. H. M. Pask, P. Dekker, R. P. Mildren, D. J. Spence, and J. A. Piper, “Wavelength-versatile visible and UV sources based on crystalline Raman lasers,” Prog. Quantum Electron. 32(3–4), 121–158 (2008). [CrossRef]  

9. P. G. Zverev, T. T. Basiev, V. V. Osiko, A. M. Kulkov, V. N. Voitsekhovskii, and V. E. Yakobson, “Physical, chemical and optical properties of barium nitrate Raman crystal,” Opt. Mater. 11(4), 315–334 (1999). [CrossRef]  

10. A. Agnesi, E. Caracciolo, L. Carrà, F. Pirzio, and G. Reali, “150-ps pulse Raman generator pumped by a 1-kHz sub-nanosecond passively Q-switched laser system,” Appl. Phys. B 107(3), 691–695 (2012). [CrossRef]  

11. A. A. Kaminskii, K. Ueda, H. J. Eichler, Y. Kuwano, H. Kouta, S. N. Bagaev, T. H. Chyba, J. C. Barnes, G. M. A. Gad, T. Murai, and J. R. Lu, “Tetragonal vanadates YVO4 and GdVO4–new efficient χ(3)-materials for Raman lasers,” Opt. Commun. 194(1–3), 201–206 (2001). [CrossRef]  

12. L. Li, Z. Liu, X. Zhang, Q. Wang, X. Wan, Z. Cong, Y. Zhang, W. Wang, and Z. Wu, “Characteristics of the temperature-tunable Nd:YAG/YVO4 Raman laser,” Opt. Lett. 37(13), 2637–2639 (2012). [CrossRef]   [PubMed]  

13. A. Lee, H. M. Pask, and D. J. Spence, “Control of cascading in multiple-order Raman lasers,” Opt. Lett. 37(18), 3840–3842 (2012). [CrossRef]   [PubMed]  

14. J. P. Feve, K. E. Shortoff, M. J. Bohn, and J. K. Brasseur, “High average power diamond Raman laser,” Opt. Express 19(2), 913–922 (2011). [CrossRef]   [PubMed]  

15. R. P. Mildren and A. Sabella, “Highly efficient diamond Raman laser,” Opt. Lett. 34(18), 2811–2813 (2009). [CrossRef]   [PubMed]  

16. L. I. Ivleva, T. T. Basiev, I. S. Voronina, P. G. Zverev, V. V. Osiko, and N. M. Polozkov, “SrWO4:Nd3+–new material for multifunctional lasers,” Opt. Mater. 23(1–2), 439–442 (2003). [CrossRef]  

17. I. V. Mochalov, “Laser and nonlinear properties of the potassium gadolinium tungstate laser crystal KGd(WO4)2: Nd3+-(KGW:Nd),” Opt. Eng. 36(6), 1660–1669 (1997). [CrossRef]  

18. T. T. Basiev, A. A. Sobol, P. G. Zverev, V. V. Osiko, and R. C. Powell, “Comparative spontaneous Raman spectroscopy of crystals for Raman lasers,” Appl. Opt. 38(3), 594–598 (1999). [CrossRef]   [PubMed]  

19. Z. Cong, X. Zhang, Q. Wang, Z. Liu, X. Chen, S. Fan, X. Zhang, H. Zhang, X. Tao, and S. Li, “Theoretical and experimental study on the Nd:YAG/BaWO4/KTP yellow laser generating 8.3 W output power,” Opt. Express 18(12), 12111–12118 (2010). [CrossRef]   [PubMed]  

20. G. M. Bonner, H. M. Pask, A. J. Lee, A. J. Kemp, J. Wang, H. Zhang, and T. Omatsu, “Measurement of thermal lensing in a CW BaWO4 intracavity Raman laser,” Opt. Express 20(9), 9810–9818 (2012). [CrossRef]   [PubMed]  

21. X. Wang, S. Wang, H. Rhee, H. J. Eichler, and S. Meister, “LD end pumped mode locked and cavity dumped Nd:YAP laser at 1.34 μm,” Opt. Commun. 284(12), 3014–3017 (2011). [CrossRef]  

22. S. Li, X. Zhang, Q. Wang, X. Zhang, Z. Cong, H. Zhang, and J. Wang, “Diode-side-pumped intracavity frequency-doubled Nd:YAG/BaWO4 Raman laser generating average output power of 3.14 W at 590 nm,” Opt. Lett. 32(20), 2951–2953 (2007). [CrossRef]   [PubMed]  

23. L. E. Batay, A. N. Kuzmin, A. S. Grabtchikov, V. A. Lisinetskii, V. A. Orlovich, A. A. Demidovich, A. N. Titov, V. V. Badikov, S. G. Sheina, V. L. Panyutin, M. Mond, and S. Kück, “Efficient diode-pumped passively Q-switched laser operation around 1.9 μm and self-frequency Raman conversion of Tm-doped KY(WO4)2,” Appl. Phys. Lett. 81(16), 2926–2928 (2002). [CrossRef]  

24. J. Zhao, X. Zhang, X. Guo, X. Bao, L. Li, and J. Cui, “Diode-pumped actively Q-switched Tm, Ho:GdVO4/BaWO4 intracavity Raman laser at 2533 nm,” Opt. Lett. 38(8), 1206–1208 (2013). [CrossRef]   [PubMed]  

25. D. G. Ran, H. R. Xia, S. Q. Sun, P. Zhao, F. Q. Liu, Z. C. Ling, W. W. Ge, H. J. Zhang, and J. Y. Wang, “Optical phonon modes and transmissivity in BaWO4 single crystal,” Cryst. Res. Technol. 41(12), 1189–1193 (2006). [CrossRef]  

26. T. T. Basiev, M. N. Basieva, A. V. Gavrilov, M. N. Ershkov, L. I. Ivleva, V. V. Osiko, S. N. Smetanin, and A. V. Fedin, “Efficient conversion of Nd:YAG laser radiation to the eye-safe spectral region by stimulated Raman scattering in BaWO4 crystal,” Quantum Electron. 40(8), 710–715 (2010). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (6)

Fig. 1
Fig. 1 Configuration of the intracavity Raman laser based on BaWO4 Raman conversion of an actively Q-switched Tm:YAP laser
Fig. 2
Fig. 2 Optical spectrum for the Raman laser based on intracavity BaWO4 Raman conversion.
Fig. 3
Fig. 3 Average output power at 1.94 and 2.36 μm as a function of incident pump power at a PRR of 1 kHz.
Fig. 4
Fig. 4 Typical oscilloscope traces of the Raman laser at a PRR of 1 kHz: (a) the pulse shape of the fundamental laser at an incident pump power of 9 W; (b) the pulse shapes for the Raman laser and fundamental laser at an incident pump power of 15.2 W.
Fig. 5
Fig. 5 Oscilloscope trace of the Raman laser at an incident pump power of 17.5 W and a PRR of 1 kHz: (a) the stretched single pulse shape; (b) the Raman laser pulse train.
Fig. 6
Fig. 6 The Raman laser output beam spatial profiles measured with a beam analyzer: (a) two dimensional distributions; (b) three dimensional distributions.

Equations (2)

Equations on this page are rendered with MathJax. Learn more.

g I th L=25/ N eff ,
N eff ( L r τ 0 c + 1 25 ln 1 R ) 1 ,
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.