Embedded pupil function recovery for Fourier ptychographic microscopy: erratum

Open Access Open Access

Abstract

In the original paper, the line width of the resolution target (which corresponds to half-pitch resolution) was used to characterize the resolution of our microscope system. However, we think that full-pitch resolution offers a better definition of the imaging system’s resolution limit. In this erratum, we list specific sections from the manuscript that used half-pitch resolution and correct them accordingly.

© 2015 Optical Society of America

In section 1, paragraph 2 of our original paper [1], we cited our first work on Fourier ptychographic microscopy [2] stating that it is ‘a high-resolution (0.78 µm, 0.5 NA), wide-FOV (~120 mm2) microscope with a final SBP of ~1 gigapixel’. As mentioned in the corrigendum of Ref. [2,3], the reported resolution for the microscope was its half-pitch resolution. However, full-pitch resolution offers a better definition of the imaging system’s resolution limit. Here we correct that the reported FPM system has 1.56 µm full-pitch resolution and ~0.23 gigapixel spatial bandwidth product.

In section 5, paragraph 3 of our original paper [1], we stated that ‘As shown in Fig. 6(c3), 6(c4), group 9 element 3 can be resolved, resulting in a resolution of ~780 µm throughout the entire FOV.’ We hereby correct this statement: ‘As shown in Fig. 6(c3), 6(c4), group 9 element 3 can be resolved, resulting in a resolution of ~1.56um throughout the entire FOV.

References and links

1. X. Ou, G. Zheng, and C. Yang, “Embedded pupil function recovery for Fourier ptychographic microscopy,” Opt. Express 22(5), 4960–4972 (2014). [CrossRef]   [PubMed]  

2. G. Zheng, R. Horstmeyer, and C. Yang, “Wide-field, high-resolution Fourier ptychographic microscopy,” Nat. Photonics 7(9), 739–745 (2013). [CrossRef]   [PubMed]  

3. G. Zheng, R. Horstmeyer, and C. Yang, “Corrigendum: Wide-field, high-resolution Fourier ptychographic microscopy,” Nat. Photonics 9(9), 621 (2015). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.