Abstract
We present a method of time coding with ABAB synchronization timing control for real-time 3D super-resolution range-gated imaging (3DSRGI). To meet the high precision of time delay and pulse width in ABAB synchronization time sequencing, phase shift is implemented to achieve ns-scaled delay and width accuracy without restoring to high clock frequencies. Theoretical analysis and experiments prove that 1 ns delay and width precision is obtained by our timing control unit based on a single field-programmable gate array with 5 ns clock cycle. Finally, a prototype experiment of 3DSRGI is demonstrated at a 10 Hz video rate with 696 pixels×520 pixels.
© 2015 Chinese Laser Press
PDF Article
More Like This
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator