Multiscale imaging of corneal endothelium damage and Rho-kinase inhibitor application in mouse models of acute ocular hypertension

Open Access Open Access

Abstract

We developed a multiscale optical imaging workflow, integrating and correlating visible-light optical coherence tomography, confocal laser scanning microscopy, and single-molecule localization microscopy to investigate mouse cornea damage from the in-vivo tissue level to the nanoscopic single-molecule level. We used electron microscopy to validate the imaged nanoscopic structures. We imaged wild-type mice and mice with acute ocular hypertension and examined the effects of Rho-kinase inhibitor application. We defined four types of intercellular tight junction structures as healthy, compact, partially-distorted, and fully-distorted types by labeling the zonula occludens-1 protein in the corneal endothelial cell layer. We correlated the statistics of the four types of tight junction structures with cornea thickness and intraocular pressure. We found that the population of fully-distorted tight junctions correlated well with the level of corneal edema, and applying Rho-kinase inhibitor reduced the population of fully-distorted tight junctions under acute ocular hypertension. Together, these data point to the utility of multiscale optical imaging in revealing fundamental biology relevant to disease and therapeutics.

© 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

1. Introduction

Biological systems coordinate multiple components within and across a wide range of lengthscales and timescales [14]. In the eye, key anatomical components, including cornea [5], iris, vitreous, lens, retina, and optic nerve head (Fig. 1(a)), collectively support its optical and neurological capabilities. The optically transparent cornea contains multiple layers, including the epithelial cell layer, endothelial cell layer, and minimally cellular stromal layer (Fig. 1(b)). The corneal epithelial and stromal layers constitute approximately one-third and two-thirds of the total thickness, and the corneal endothelial cells (CECs) form an only ∼2-µm thick monolayer on the inner surface of the cornea [6]. Corneal dysfunction often lead to vision loss and blindness, affecting more than 12.7 million people globally [4,7]. CEC function in dehydrating the stroma and maintaining corneal clarity is fundamentally powered by nanoscale biomolecular machinery, assemblies into subcellular organelles, and maintenance of intercellular tight junctions [2,812]. Morphological and physiological changes of the cornea as a whole can also affect its cellular and biomolecular activities [1,2,812]. Therefore, multiscale analyses, covering lengthscales from the in vivo whole cornea anatomy to intracellular and intercellular single molecules, are important to comprehensively understand corneal health, diseases, and biological response to candidate therapies.

 figure: Fig. 1.

Fig. 1. Sample caption (Ref. [4], Fig. 2) The multiscale imaging workflow. (a) Illustration of a mouse eye; (b) A histological image of mouse cornea; (c) Comparing imaging resolution and penetration depth among OCT, CLSM, and SMLM; (d) An in-vivo vis-OCT B-scan image of a wild-type mouse cornea; (e) A 3D visualization using CLSM of a fixed mouse cornea flat-mount immunofluorescent labeled with a tight junction marker (ZO-1, red) and nuclear stain (DAPI, blue); (f) An CLSM image of the CEC tight junctions showing the classical hexagonal boundaries; (g) A magnified view of the area highlighted in panel e; (h) An SMLM image, with a similar FOV as the panel g, visualizing the nanoscale structures and filaments of the ZO-1 organizations between adjacent cells.

Download Full Size | PDF

Acute ocular hypertension (AOH) and the progression of acute primary angle closure glaucoma (APACG) can cause damage and dysfunction in CECs, leading to vision loss [13]. Recent studies found that adding Rho-kinase (ROCK) inhibitor eye drops promoted corneal endothelial wound healing in different animal models [1420]. ROCK signaling pathways contribute to various cellular functions, such as cell adhesion, motility, proliferation, differentiation, and apoptosis [21,22]. The role of ROCK has been intensively investigated as a therapeutic target in a broad spectrum of diseases such as vascular disease, cancer, degenerative neuronal disease, asthma, and glaucoma [14,16,17,19,20,2326]. Using multiscale imaging, researchers can investigate the effect of ROCK-inhibitor on the overall corneal damage and intracellular damage among CECs in the mouse model of AOH [27]. The mouse models of AOH have been broadly used to study various sequelae of glaucoma in both the anterior and posterior segments, where it induces significant changes in endothelial density, morphology, and nanoscale tight junction structures. At the subcellular level, damage in CEC tight junctions could lead to an uncontrolled fluid passage from the anterior chamber, causing corneal edema and stroma damage, and ultimately vision loss [27]. In this work, we established the workflow of multiscale cornea imaging in wild-type mice and quantified corneal and CEC damages and ROCK-inhibitor effects in mice with AOH.

To satisfy the need for multiscale analysis, we combined three optical imaging modalities with complementary resolutions and contrasts to perform investigations from the in vivo intact cornea to nanoscale intercellular structures (Fig. 1(c)). At the in-vivo intact cornea level, we applied noninvasive visible-light optical coherence tomography (vis-OCT), which can achieve an axial resolution of 1.3 µm and image the entire mouse anterior segment (Fig. 1(c) top right region) [2830], to monitor overall corneal health or damage in mice. At the ex-vivo cellular level, we applied confocal laser scanning microscopy (CLSM), which offers a lateral resolution of up to 200 nm and an imaging penetration depth of up to several hundred micrometers (Fig. 1(c) center region) [31], to classify CECs in flat-mount corneal tissue samples. However, due to the optical diffraction limit, CLSM cannot resolve nanoscale intercellular structures [32]. We recently developed a super-resolution optical imaging workflow to visualize, for the first time, the nanoscale subcellular structures in the corneal endothelium using single-molecule localization microscopy (SMLM) [33]. SMLM offers a spatial resolution of 20 nm at a penetration depth of a few micrometers (Fig. 1(c) bottom left region) [3437]. Hence, at the nanoscopic level, we applied SMLM to image intercellular nanostructures in CECs.

More specifically, we used vis-OCT to quantify the corneal anatomy in vivo (Fig. 1(d)); then, we used CLSM to image CEC’s morphological labeled by a tight junction Zonula occludens-1 (ZO-1) protein (Figs. 1(e)–1(f)) in flat-mount cornea samples; and finally, we used SMLM to quantify nanoscale morphological variations of ZO-1 labeled tight junctions and validated by scanning electron microscopy (SEM) in flat-mount cornea samples (Fig. 1(g)), where the tight junction nanostructures are not resolvable by CLSM (Fig. 1(h)).

2. Methods and materials

Figure 2 shows our multiscale imaging workflow, from generating the mouse models, tissue harvesting, immunofluorescence staining, to CLSM, SMLM and SEM imaging. First, we treated the left eyes of young mice at 8-12 weeks of age with ROCK-inhibitor (ROCK group) or DMSO (control group) at four drops a day for 14 days. Then, we acquired in vivo vis-OCT images of left corneas before AOH in both groups. To introduce AOH, we cannulated the anterior chamber of the left eye to induce elevated IOP (∼40 mmHg) in the AOH groups for one hour. We cannulated and maintained an IOP at 8 mmHg for one hour in the normal IOP control groups. After a second round of in vivo imaging, we harvested the left corneas, fixed them, and immunofluorescent-labeled them to visualize ZO-1 or other intracellular structures of interest. Finally, we acquired CLSM, SMLM, and SEM images of the cornea samples for further analysis.

 figure: Fig. 2.

Fig. 2. Experimental protocol for generating mouse models of AOH and subsequent application of ROCK inhibitor.

Download Full Size | PDF

2.1 AOH mice model generation

We used 8-12 weeks-old Wild-type C57BL/6 mice in our studies. The experimental animals were kept in the Center for Comparative Medicine at Northwestern University under normal lighting conditions with 12-h on and 12-h off cycles. All animal protocols were approved by the Institutional Animal Care and Use Committees of Northwestern University and conformed to the Association for Research in Vision and Ophthalmology Statement on Animal Research.

To create AOH, the mice were anesthetized via intraperitoneal injection (10 mL/kg body weight) of a ketamine/xylazine cocktail (ketamine: 11.45 mg/mL; xylazine: 1.7 mg/mL, in saline). We maintained the mouse body temperature within 34-36 °C using a rectal temperature probe (FHC Inc., catalog # 40-90-8D) with temperature feedback and its attached thermal heating pad. We used lidocaine as the lubricant for the temperature probe. We applied 1% Povidone-iodine for 60 seconds to the left eye and then washed the eyes with sterile PBS for conjunctival sac disinfection for 60 seconds. We inserted a 33-Gauge needle from the marginal cornea into the anterior chamber of the left eye. We checked the integrity of the iris under a surgical microscope before proceeding. Using manometry, we stabilized the needle with external mechanical support and controlled the IOP [38]. More specifically, the eye was cannulated and connected to a syringe filled with PBS containing 5% mmol/L glucose. We controlled the IOP by adjusting the height of the syringe relative to the mouse eye. We elevated the syringe position to ∼55 cm above the mouse eye, corresponding to an IOP of around 40 mmHg, and maintained it for 1 hour. Afterward, we adjusted the syringe position to be ∼10 cm above the eye, corresponding to an IOP of 8 mmHg, and performed in vivo imaging. We documented the IOP every 15 minutes using a tonometer (iCare TONOLAB) and applied artificial tears (Alcon, NDC 17478-062-35) every 2 minutes. In addition, we checked the toe pinch reflex and respiratory rate every 15 minutes to ensure deep anesthesia.

2.2 ROCK inhibitor application

To prepare the ROCK inhibitor solution, we first dissolved solid Y-27623 (Cayman Chemical 1000558310) in DMSO to achieve a concentration of 0.1 M and then diluted it with PBS to achieve a final concentration of 200 µM. For topical administration, we first immersed a sterile cotton tip applicator in the Y-27623 solution; then, we gently wiped the tip of the cotton tip applicator on the surface of the left cornea and repeated it four times with an interval of 10 minutes. In the control group, we applied a solution of 200 µM DMSO in PBS using the same method. We repeated all topical administrations daily for 14 days in both groups.

2.3 In vivo vis-OCT imaging

We imaged the cornea using a custom-built vis-OCT system, operating between 510 nm and 610 nm [3841]. The vis-OCT used an incident power of 1.5 mW on the cornea, and our imaging field of view was 2.7 × 2.7 mm2, containing 1024 × 1024 A-lines. The vis-OCT system provides an axial resolution of 1.3 µm and a lateral resolution of 6.8 µm in the cornea [38]. We conducted in vivo vis-OCT imaging immediately after the AOH procedure without removing the needle. We applied artificial tears every 2 minutes during data acquisition to prevent corneal dehydration. Before measuring corneal thickness, we manually segmented each anatomical layer in the central corneal region. Four members independently measured the thickness of each corneal anatomical layer using ImageJ line profile measurement, and we reported the mean values in this work.

2.4 Corneal sample preparation for CLSM and SMLM

After vis-OCT imaging, we removed the needle, euthanized the mice by cervical dislocation, and retrieved the cornea immediately. We first rinsed the cornea with PBS to remove any blood, pigment, and tissue residues attached to the cornea. Then, we cut the cornea into four equal pieces and fixed them in 0.5% Paraformaldehyde (PFA) at 25°C for 30 mins. The cornea samples were permeabilized with 1% Triton X-100 in PBS at 25°C for 30 min and blocked in 2% normal goat serum, 2% bovine serum albumin (BSA), and 1% Triton 100-X in PBS at 25°C for 2 hours. The cornea samples were further incubated with a primary antibody targeting a tight junction marker protein (ZO-1, #40-2200, Invitrogen) at 4°C for 48 hours. Lastly, the cornea samples were incubated with a secondary antibody (anti-rabbit Alexa Fluor 647, Thermofisher) at 4°C for 12 hours. We rinsed the cornea samples three times for 20 min at 25°C after each fixation, primary antibody incubation, and secondary antibody incubation step.

2.5 SMLM imaging

After immunostaining, we placed the cornea samples on a rectangular No. 1.5 cover glass (22 × 60 mm2) with the CECs facing down according to the physiological curvature of the cornea and applied a few strips of double-sided tapes on the cover glass around the cornea samples. Next, we gently flattened the cornea sample using ophthalmic micro forceps, removed excessive PBS around the tissue samples, and covered the cornea samples with a No. 1 square cover glass (22 mm) to create an imaging chamber with the double-sided tapes. Finally, we fill the imaging chamber with an appropriate imaging buffer solution for SMLM.

Before each imaging, we freshly prepared the imaging buffer solution containing 50 mM Tris (pH =8.0), 10 mM NaCl, 0.5 mg/mL glucose oxidase (Sigma, G2133), 2000 U/mL catalase (Sigma, C30), 10% (w/v) D-glucose, and 100 mM cysteamine. We added ∼10 µL of the imaging buffer to fill the imaging chamber and sealed it with black nail polish to prevent leaking during the imaging process. We refilled the imaging buffer every two hours in prolonged SMLM data acquisition sessions. Finally, we mounted the imaging chamber onto the SMLM microscope with the rectangular cover glass facing downward.

For SMLM imaging acquisition, we used a Nikon Ti-2E fluorescence microscope with a 100× objective lens (Nikon SR HP Apo TIRF, 100×) and a 647-nm continuous-wave laser to illuminate the sample using a highly inclined and laminated optical sheet (HILO) illumination with an angle slightly smaller than the critical angle at a power density of about 5 kW cm-2, as previously reported. [33,4244]. The exposure time of each SMLM frame was 10 ms, and we acquired 30,000 frames from each sample for image reconstruction using the ThunderSTORM plug-in of ImageJ [45].

2.6 CLSM imaging

We mounted the cornea samples in the same manner as we did for SMLM imaging. However, instead of the aforementioned imaging buffer solution, we used a PBS solution containing 1-µM Hoechst 33328 to fill the imaging chamber and counterstain the cell nucleus. We used a Leica SP5 confocal microscope to acquire all our CLSM images using a 20 × oil immersion objective lens with a pixel size of 1 µm except Fig. 1(g) using a 60 × oil immersion with a pixel size of ∼300 nm.

2.7 SEM imaging

We first fixed the cornea samples in a solution containing 2.5% glutaraldehyde and 4% PFA in a 0.1 M sodium cacodylate buffer pH 7.4. Then we fixed the corneal samples further with 1% osmium tetroxide and dehydrated them in a graded series of ethanol (30%, 50%, 70%, 85%, 95%) before critical point drying in a Tousimis Samdri-795 critical point drier. Before SEM imaging, we mounted the processed corneas to an aluminum SEM stub with carbon tape and silver paint and sputter-coated with 10 nm of Au/Pd in a Denton Desk IV sputter coater. Finally, we imaged all samples using a Hitachi SU8030 cFEG SEM at 10 kV.

3. Results

3.1 In-vivo vis-OCT imaging measured bulk anatomical alterations in mouse corneas

Figure 3 and Table 1 show the in vivo vis-OCT [38] imaging of the corneas to assess the effects of AOH and ROCK inhibitor application. We compared the central corneal thickness of four groups: group C1 with normal IOP and DMSO treatment, group C2 with AOH and DMSO treatment, group C3 with normal IOP and Y-27623 treatment, and group C4 with AOH and Y-27623 treatment. Figures 3(a)–3(d) respectively show representative vis-OCT images from each of the four groups. In the control group C1 (Fig. 3(a)), vis-OCT well resolved the epithelium, stroma, and endothelium layers thanks to its 1.3-µm axial resolution [46], making it possible to measure variations in the thickness of these layers. Figure 3(b) shows that AOH significantly increased stromal thickness with characteristic edema in group C2 compared with group C1. Figure 3(c) shows that topical administration of Y-27623 in group C3 induced no change in corneal thickness compared to the control group C1. The cornea treated with Y-27623 (Fig. 3(d)) in group C4 exhibited less severe edema and a minor increase in stromal thickness compared with the untreated cornea subjected to AOH in group C2 (Fig. 3(b)).

 figure: Fig. 3.

Fig. 3. In vivo vis-OCT image of mouse cornea at four conditions. (a) Condition C1 with normal IOP and DMSO treatment; (b) Condition C2 with elevated IOP and DMSO treatment; (c) Condition C3 with normal IOP and Y-27623 treatment; (d) Condition C4 with elevated IOP and Y-27623 treatment; (e) Total corneal thickness variation; (f) Stromal thickness variation; (g) Corneal epithelium thickness variation; (h) Corneal endothelium thickness variation. N = 3 for each condition.

Download Full Size | PDF

Tables Icon

Table 1. In vivo thickness measurements by vis-OCT (± denotes standard deviations.)

Next, we compared vis-OCT-measured thickness variations of the total cornea, epithelium, stroma, and endothelium in the four groups, as shown in Table 1 and Figs. 3(e)–3(h). In the control group C1, the corneal epithelium, stroma, and endothelium showed average thicknesses of 37.4 µm, 64.2 µm, and 4.5 µm, respectively, and the average total corneal thickness was 104.2 µm. The baseline corneal thickness in C1 is consistent with other studies for C57BL/6 mice, which measured an average thickness of 100.8 ± 5.7 µm [47]. Compared with the C1 group, the total corneal thickness increased 4-fold and 3-fold in group C2 and group C4, respectively, (Fig. 3(e)), stromal thicknesses increased 5-fold and 4-fold in the C2 and C4 groups, respectively (Fig. 3(f)), and epithelium thickness increased 2-fold in the C2 group (Fig. 3(g)). The reductions in the total cornea and stroma thicknesses are statistically significant between the C2 and C4 groups, suggesting topical administration of Y-27623 reduced edema in corneas subjected to AOH. However, we did not observe statistically significant changes in the endothelium (Fig. 3(h)) thicknesses in groups C2 and C4 compared with group C1. In addition, we did not observe statistically significant thickness changes in the total cornea, epithelium, stroma, and endothelium between the groups C1 and C3, suggesting no effect from the topical administration of DMSO versus ROCK inhibitor in corneas not subjected to AOH insult.

3.2 CLSM imaging classified CECs based on different ZO-1 morphologies

After in vivo vis-OCT imaging, we harvested the corneas and examined the CEC morphological changes in the four groups. Multiple studies reported the influence of external conditions such as elevated IOP [16,18] or perfusion with diamide [48], on cell-cell junctions in CECs that play key roles in endothelial permeability. Figure 4 shows representative CLSM images of CECs in groups C1-C4, where the cell nuclei are pseudo-colored in blue, and the labeled ZO-1 tight junctions are pseudo-colored in red. Tile-scan epifluorescence microscopy images are shown in Supplementary Figs. S1-S4. Although previous studies observed tight junction disruption in rat corneas under AOH [27], we categorized the tight junction morphologies into four types from CLSM images, which we further correlated with vis-OCT and SMLM findings.

 figure: Fig. 4.

Fig. 4. Representative CLSM images of a cluster of CECs (a) Normal Type 1 ZO-1 structures; (b) Compact Type 2 ZO-1 structures; (c) Partially-distorted Type 3 ZO-1 structures; (d) Fully-distorted Type 4 ZO-1 structures; (e) Statistics of cell population exhibiting the four types of ZO-1 structures among 500-1500 cells from three mice; (f) Scatterplot of cell population measured from CLSM versus total corneal thickness measured from vis-OCT. Error bar: standard deviation; n = 4.

Download Full Size | PDF

In a healthy cornea, ZO-1 is known to form regular hexagonal or pentagonal patterns in CECs and is organized continuously in adjacent cell borders, which we define as Type 1 structures (Fig. 4(a)). Figure 4(b) shows that ZO-1 can still form the hexagonal or pentagonal patterns but exhibits more compact and slightly torturous boundaries among adjacent cells, which we define as Type 2 structures. Figure 4(c) shows highly torturous and discontinuous ZO-1 structures with partial distortion among neighboring cells, which we define as Type 3 structures. Lastly, Fig. 4(d) shows ZO-1 structures severely pulled apart among the adjacent cell border with ZO-1 nanofibers stretched from the cell borders, which we define as Type 4 structures.

Based on the four defined ZO-1 morphological types, we obtained their respective statistical distributions in groups C1-C4. We imaged 500-2000 CECs from three mice in each group using epifluorescence microscopy with tile-scan function (Ti2E, Nikon). Four lab members independently classified ZO-1 structures from Type 1 to Type 4 based on the above definition. Figure 4(e) and Table 2 show the percentage populations of the four CECs types. Among all the CECs ZO-1 labeled cell junctions from the groups C1 and C3, 90%-95% were Type 1, 3% were Type 2, and <0.2% were Type 4. We found 6.6% and 1.2% Type 3 CECs in groups C1 and C3, respectively. In group C2, the Type 1 CECs population dropped to 16%, with an increase of Type 2, Type 3, and Type 4 CECs to 32.6%, 25.3%, and 25.8%, respectively. In group C4, 30.92% CECs remained healthy (Type 1), and the populations for Type 2, Type 3, and Type 4 CECs changed to 40.51%, 16.49%, and 5.83%, respectively. Compared with group C2, higher populations of Type 1 and Typ2 CECs in the Y-27623 treated group C4 contributed to the less severe edema in the stroma, agreeing with the in vivo thickness measurements by vis-OCT. Figure 4(f) shows the percentage populations of the four types of CECs with respect to the corresponding total corneal thickness. When the total corneal thickness increased, the percentage population of the normal Type 1 CECs (blue squares) dropped, and the percentage populations of the Types 2-4 CECs increased.

Tables Icon

Table 2. Percentage population of the four types of ZO-1 structures in CECs imaged by CLSM.

3.3 SMLM visualization of the four types of the ZO-1 nanostructures

Although we qualitatively identified four types of CECs with distinct ZO-1 structures, the exact ZO-1 morphology at the nanoscopic scale remains unresolvable by CLSM due to its diffraction-limited spatial resolution (Fig. 1(g)). To quantitatively define the ZO-1 nanostructure in these four types, we applied SMLM to both visualize and measure the width of ZO-1 labeled intercellular CEC junctions. Compared with CLSM imaging, we focused on a much smaller FOV in SMLM.

In Type 1 ZO-1 structures (Fig. 5(a)), we observed unique nanoscopic organizations of tight junctions organized along the boundaries between adjacent CECs with an average width of 1.3 µm (highlighted by solid yellow lines). We also observed the discontinuity of the ZO-1 pattern at the Y-junction where the three cells intersect, a known nanoscale feature of tight junctions associated with the relatively low-stress resistance of corneal endothelium [49] (highlighted by the green arrow in Fig. 5(a)). Interestingly, we also observed fine discontinued nanoscale pores along the cell-cell borders, as the blue arrow indicated area with a pore size of ∼600 nm2. For the Type 2 ZO-1 structures, SMLM (Fig. 5(b)) shows compact tight junctions with an average width of 0.4 µm. The discontinuity of these ZO-1 structures is reduced or disappeared at the Y-junctions and along the cell borders (green arrows in Fig. 5(b)) compared to the Type 1 ZO-1 structure. In a typical Type 3 ZO-1 structure, elevated discontinuity boundaries among adjacent cells with distorted fiber branches are visualized (Fig. 5(c)), where the non-distorted portion of the ZO-1 structure width is comparable to the Type 2 ZO-1 structure. Lastly, the Type 4 ZO-1 structure shows complete separations of the tight junctions between adjacent cells along the cell borders and at the Y-junctions, with individual junction fibers clearly visualized (Fig. 5(d)).

 figure: Fig. 5.

Fig. 5. SMLM images of (a) Type 1, (b) Type 2, (c) Type 3, and (d) Type 4 ZO-1 structures in CECs. The solid yellow lines in each panel illustrate the unambiguous thickness measurement of tight junction thickness using SMLM. The green and blue arrow-pointed areas indicate the classical tight junction discontinuities at three-cell Y-junctions and newly-discovered tight junction pores using SMLM. SEM images of CECs with (e) healthy tight junctions; (f) partially damaged tight junctions; (g) fully-distorted tight junctions. Yellow arrows point to tight junctions. (h) Tight junction widths measured from SMLM from the four types of CECs from the solid yellow lines. N = 5; (i) Line profiles of the stretched intercellular space ZO-1 nanofiber from the positions highlighted by the white dashed lines in panels d and g; the green scales indicate the ZO-1 fiber thickness measurement from the SEM image.

Download Full Size | PDF

To further validate SMLM-imaged ZO-1 nanostructures, we imaged the four types of ZO-1 structures using SEM. Due to SEM’s imaging contrast limit, we could only visualize the superficial morphologies of the CECs without any specificity to ZO-1 proteins. From the SEM images, we examined how tightly adjacent cells are bonded in the four types of CECs. Figure 5(e) shows similar cell boundaries that match the normal (Type 1) or compact (Type 2) ZO-1 structures shown in Figs. 5(a)–5(b). SEM images of Type 3 CECs showed similar “wrinkled” boundaries and partial separations between cells, as shown in Fig. 5(f). For the Type 4 ZO-1 structure, SEM captured the stretched junction fibers when tight junctions were separated by the elevated IOP (Fig. 5(g)), closely matching the SMLM image shown in Fig. 5(d).

We compared the SMLM measured ZO-1 structure widths among the four CEC types in Fig. 5(h) and Table 3, where the averaged widths of the four types are 1.3 µm, 0.4 µm, 0.6 µm, and 8.9 µm, respectively. Except for the ZO-1 structures between Type 2 and Type 3 CECs, all other ZO-1 structure types showed statistically significant differences in width. We also compared the sizes of individual junction fibers in Type 4 CECs imaged by SMLM and SEM (Fig. 5(i)) as the intensity profiles from the positions highlighted by the white dashed lines in Figs. 5(d) & 5(g). Particularly, the full-width-at-half-maximum (FWHM) fiber size is ∼ 50 nm in SMLM, while those from the SEM measurements (inner-membrane distance as indicated by the green scales in Fig. 5(i)) were ∼30-50 nm. In summary, these nanoscale features visualized by both SMLM and SEM consistently showed a significantly increased ZO-1 width among CECs subjected to elevated IOP.

Tables Icon

Table 3. SMLM measured widths of the four types of ZO-1 structures in CECs.

4. Discussion

In this work, we report a multiscale workflow to image mouse cornea from the in vivo tissue level, including corneal thickness, to the ex vivo single-molecule level, including nanoscale morphological changes in the ZO-1-labeled CEC tight junctions. Correlating OCT and fluorescence microscopy has been widely used to study cellular and subcellular damage associated with eye diseases. [28] However, the spatial resolutions of conventional fluorescence microscopy technologies are fundamentally constrained by the optical diffraction limit, which prevents the visualization of underlying nanoscopic and molecule processes at the subcellular level. SMLM overcomes the diffraction limit and offers a resolution down to ∼10 nm. [35] However, SMLM requires stringent sample preparation protocols to preserve the nanoscale ultrastructure and minimize non-specific single-molecule labeling, which might not be detected in conventional fluorescence microscopy because of SMLM’s single-molecule detection sensitivity. Therefore, we investigated the concentration, temperature, and incubation time in the fixation and antibody labeling steps, respectively, as detailed in the Methods and materials section, to obtain the optimal sample preparation conditions for SMLM imaging of ZO-1 in the mouse corneal flatmount [33].

There are several limitations in SMLM imaging for mouse ocular tissue. SMLM typically has a limited imaging depth of the field of ∼1-2 µm and an imaging penetration depth of ∼10 µm. [50] This is because SMLM requires the collection of precious photons (<104) emitted from the individual fluorescent labels with minimal optical attenuations and aberrations to localize single-molecule locations at nanometer precision. When applying SMLM to image tissue samples, only the biological structures that are close (< 10 µm) to the interface between the cover glass and the tissue sample can be routinely imaged. Imaging beyond a few µm range into the cornea is challenging due to the elevated autofluorescence background and the reabsorption and scattering of the emitted single-molecule fluorescence signal. Further technological developments to provide optical sections, brighter fluorescent labels, and imaging processing methods to analyze single-molecule emitters in deep ocular tissue could facilitate the visualization of other eye tissues at the nanoscale. Another potential option is to utilize multiphoton microscopy, which has deeper penetration depth (up to 1 mm) than SMLM and better spatial resolution than CLSM. However, the spatial resolution for multiphoton microscopy is still diffraction limited [51].

This new multiscale imaging workflow allowed the first correlation studies of clinically-relevant damage in the mouse cornea. First, we revealed nanoscopic variations of ZO-1 labeled tight junctions under the influence of AOH and subsequent ROCK inhibitor protection, as shown in Fig. 5. Under AOH, the observed tight junction nanofibers among adjacent cells in Figs. 5(d)&5(g) are likely attributed to the tunneling membrane nanotubes (TMT) based on their closely resembled morphologies compared with prior reports. TMTs are defined as membrane protrusions with thicknesses of a few hundred nanometers and lengths at the micrometer scale, which link distant cell bodies [52,53]. TMT-like structures have been found in diverse mammalian cells, such as retinal pigment epithelial cells, dendritic cells in the corneal stroma, neuroblastoma cells, and breast cancer cells. However, to the best of our knowledge, this is the first report to visualize the formation of TMTs in native tissue at the nanoscopic level by both SMLM and SEM. TMTs in the corneal endothelium under AOH presumably alter Ca2+ and other biomolecular signal transduction in extended ranges of signal communication so that cell-cell communication is maintained without using classical gap junction-mediated short-range signaling. We believe the nanoscale Type 4 ZO-1 structures (< 100 nm fibers) are not similar to microfilaments observed after corneal perfusion with diamide [48]. Those microfilaments are formed on the edges among different clusters of CECs induced after corneal perfusion, while the TMT is observed between individual CECs (Fig. 5(g)). However, we also note that the typical TMT forms between the gap junctions other than tight junctions where ZO-1 primarily highlights the latter [52]. One hypothesis is that ZO-1 is mobile and can bind to stably arranged gap junction plaques, thus contributing to the formation of TMT [54].

This newly developed multiscale imaging workflow demonstrated that applying a ROCK inhibitor can reduce the population of severely damaged ZO-1 structures and the severity of corneal edema in mouse models subjected to AOH (Figs. 35). Additionally, our results support the hypothesis that ROCK inhibitor Y-27632 therapy may protect CECs from AOH, consistent with a previous report that found Y-27632 treatment helped maintain corneal clarity following APACG [55] by increasing aqueous outflow and reducing IOP [56]. Now our multiscale imaging workflow provides new insights into the subcellular alterations induced by ROCK inhibitors in CECs, and suggests a mechanism of action for ROCK inhibition’s effect maintaining corneal clarity, namely protecting or reverting the inter-cellular morphologies of tight junctions in CECs. The detailed molecular pathways involved in AOH and ROCK inhibitor therapy on CECs remain open questions but can in future work from hypotheses generated here.

5. Conclusion

We developed a multiscale corneal imaging workflow focusing on the corneal endothelium. For the first time, we revealed the alterations in tight junctions of the cornea endothelium at the nanoscopic level. Sub-100-nm ZO-1 tight junction fibers, likely the tunneling membrane nanotubes, perpendicular to the cell border, were observed among CECs. The vis-OCT-CLSM-SMLM correlation further suggests a close correlation between cornea and endothelium thicknesses and the percentile populations of four different CEC types. In the AOH model, the probabilities of CECs with the tight junction structure becoming more compact or stretched are 10-fold and >1000-fold higher than the healthy cornea. ROCK inhibitor application reduced the severely damaged CECs population by ∼80%. Detailed mechanisms inducing the stretched CECs and ROCK inhibitor effect in CECs under different levels of IOPs longitudinally should be further investigated.

Funding

National Institutes of Health (F30EY034033, P30EY026977, R01EY029121, R01EY034740, R01GM139151, R01GM140478, R01GM143397, R21GM141675, U01EY033001, U54CA268084); National Science Foundation (CHM-1954430, EFMA-1830969); Illinois Society for the Prevention of Blindness; Research to Prevent Blindness.

Acknowledgment

This work was supported in part by NIH grants R01EY029121, U01EY033001, R01EY034740, R01GM139151, R01GM140478, R01GM143397, U54CA268084, P30EY026977, and F30EY034033; NSF grants CHM-1954430 and EFMA-1830969; Research to Prevent Blindness, Inc., and a seed grant from Illinois Society for the Prevention of Blindness. We thank Northwestern Biological Imaging Facility (BIF), Mouse Histology and Phenotyping Lab (MHPL), Center of Advanced Molecular Imaging (CAMI), and Atomic and Nanoscale Characterization Experimental Center (NUANCE) core facilities for sample preparation and image acquisition support. The authors also thank Dr. Angelo Tanna for fruitful discussions.

Disclosures

RSF: Northwestern (P); CS: Northwestern (P), Opticent Health (I, C), JLG: Opticent Health (I); HFZ: Northwestern (P), Opticent Health (I,C)

Data Availability

Raw data presented in this paper is not yet publicly available but is available upon reasonable request.

Supplemental document

See Supplement 1 for supporting content.

References

1. W. L. Edda Klipp, Christoph Wierling, and Axel Kowald, Systems Biology: A Textbook, 2nd Edition (Wiley-Blackwell, 2016).

2. B. Alberts, D. Bray, J. Lewis, et al., Molecular Biology of the Cell6th Edition (Garland Science, 2014).

3. D. T. Rowlands, Human Pathology: An Introduction to the Study of Disease (Macmillan Pub. Co., 1986).

4. D. U. Silverthorn, Human Physiology: An Integrated Approach 5th Edition (Benjamin Cummings, 2011).

5. J. L. McGreeley, Encyclopedia of Eye Research 1st Edition (Nova Biomedical Books, 2011).

6. J. T. Henriksson, A. M. McDermott, and J. P. Bergmanson, “Dimensions and morphology of the cornea in three strains of mice,” Invest. Ophthalmol. Vis. Sci. 50(8), 3648–3654 (2009). [CrossRef]  

7. J. D. Steinmetz, R. R. A. Bourne, P. S. Briant, et al., “Causes of blindness and vision impairment in 2020 and trends over 30 years, and prevalence of avoidable blindness in relation to VISION 2020: the Right to Sight: an analysis for the Global Burden of Disease Study,” The Lancet Global Health 9(2), e144–e160 (2021). [CrossRef]  

8. J. Caplan, M. Niethammer, R. M. Taylor, et al., “The power of correlative microscopy: multi-modal, multi-scale, multi-dimensional,” Curr. Opin. Struct. Biol. 21(5), 686–693 (2011). [CrossRef]  

9. T. Furuta, K. Yamauchi, S. Okamoto, et al., “Multi-scale light microscopy/electron microscopy neuronal imaging from brain to synapse with a tissue clearing method, ScaleSF,” iScience 25(1), 103601 (2022). [CrossRef]  

10. A. K. Glaser, K. W. Bishop, L. A. Barner, et al., “A hybrid open-top light-sheet microscope for versatile multi-scale imaging of cleared tissues,” Nat. Methods 19(5), 613–619 (2022). [CrossRef]  

11. R. M. Power and J. Huisken, “A guide to light-sheet fluorescence microscopy for multiscale imaging,” Nat. Methods 14(4), 360–373 (2017). [CrossRef]  

12. S. Tang, Y. Zhou, K. K. H. Chan, et al., “Multiscale multimodal imaging with multiphoton microscopy and optical coherence tomography,” Opt. Lett. 36(24), 4800–4802 (2011). [CrossRef]  

13. A. Petsas, G. Chapman, and R. Stewart, “Acute angle closure glaucoma - A potential blind spot in critical care,” J. Intensive Care Soc. 18(3), 244–246 (2017). [CrossRef]  

14. N. Okumura, S. Kinoshita, and N. Koizumi, “Application of Rho Kinase Inhibitors for the Treatment of Corneal Endothelial Diseases,” J. Ophthalmol. 2017, 2646904 (2017). [CrossRef]  

15. N. Okumura, R. Inoue, Y. Okazaki, et al., “Effect of the Rho Kinase Inhibitor Y-27632 on Corneal Endothelial Wound Healing,” Invest. Ophthalmol. Visual Sci. 56(10), 6067–6074 (2015). [CrossRef]  

16. N. Okumura, Y. Okazaki, R. Inoue, et al., “Effect of the Rho-Associated Kinase Inhibitor Eye Drop (Ripasudil) on Corneal Endothelial Wound Healing,” Invest. Ophthalmol. Visual Sci. 57(3), 1284–1292 (2016). [CrossRef]  

17. N. Okumura, Y. Sakamoto, K. Fujii, et al., “Rho kinase inhibitor enables cell-based therapy for corneal endothelial dysfunction,” Sci. Rep. 6(1), 26113 (2016). [CrossRef]  

18. N. Okumura, Y. Okazaki, R. Inoue, et al., “Rho-Associated Kinase Inhibitor Eye Drop (Ripasudil) Transiently Alters the Morphology of Corneal Endothelial Cells,” Invest. Ophthalmol. Visual Sci. 56(12), 7560–7567 (2015). [CrossRef]  

19. A. Pipparelli, Y. Arsenijevic, G. Thuret, et al., “ROCK inhibitor enhances adhesion and wound healing of human corneal endothelial cells,” PLoS One 8(4), e62095 (2013). [CrossRef]  

20. N. Okumura, N. Koizumi, E. P. Kay, et al., “The ROCK inhibitor eye drop accelerates corneal endothelium wound healing,” Invest. Ophthalmol. Visual Sci. 54(4), 2493–2502 (2013). [CrossRef]  

21. M. Amano, M. Nakayama, and K. Kaibuchi, “Rho-kinase/ROCK: A key regulator of the cytoskeleton and cell polarity,” Cytoskeleton 67(9), 545–554 (2010). [CrossRef]  

22. A. P. Somlyo and A. V. Somlyo, “Signal transduction by G-proteins, rho-kinase and protein phosphatase to smooth muscle and non-muscle myosin II,” J. Physiol. 522(Pt 2), 177–185 (2000). [CrossRef]  

23. G. Al-Humimat, I. Marashdeh, D. Daradkeh, et al., “Investigational Rho Kinase Inhibitors for the Treatment of Glaucoma,” J. Exp. Pharmacol. 13, 197–212 (2021). [CrossRef]  

24. Y. Feng, P. V. LoGrasso, O. Defert, et al., “Rho Kinase (ROCK) Inhibitors and Their Therapeutic Potential,” J. Med. Chem. 59(6), 2269–2300 (2016). [CrossRef]  

25. M. Dong, B. P. Yan, J. K. Liao, et al., “Rho-kinase inhibition: a novel therapeutic target for the treatment of cardiovascular diseases,” Drug Discovery Today 15(15-16), 622–629 (2010). [CrossRef]  

26. J. Liu, H. Y. Gao, and X. F. Wang, “The role of the Rho/ROCK signaling pathway in inhibiting axonal regeneration in the central nervous system,” Neural Regener. Res. 10(11), 1892–1896 (2015). [CrossRef]  

27. X. Li, Z. Zhang, L. Ye, et al., “Acute ocular hypertension disrupts barrier integrity and pump function in rat corneal endothelial cells,” Sci. Rep. 7(1), 6951 (2017). [CrossRef]  

28. X. Shu, L. Beckmann, Y. Wang, et al., “Designing visible-light optical coherence tomography towards clinics,” Quantitative Imaging in Medicine and Surgery 9(5), 769–781 (2019). [CrossRef]  

29. D. A. Miller, M. Grannonico, M. Liu, et al., “Visible-Light Optical Coherence Tomography Fibergraphy for Quantitative Imaging of Retinal Ganglion Cell Axon Bundles,” Trans. Vis. Sci. Tech. 9(11), 11 (2020). [CrossRef]  

30. Z. Ghassabi, R. V. Kuranov, J. S. Schuman, et al., “In Vivo Sublayer Analysis of Human Retinal Inner Plexiform Layer Obtained by Visible-Light Optical Coherence Tomography,” Invest. Ophthalmol. Visual Sci. 63(1), 18 (2022). [CrossRef]  

31. A. D. Elliott, “Confocal microscopy: principles and modern practices,” Curr. Protoc. Cytom. 92(1), e68 (2020). [CrossRef]  

32. G. Vicidomini, P. Bianchini, and A. Diaspro, “STED super-resolved microscopy,” Nat. Methods 15(3), 173–182 (2018). [CrossRef]  

33. Z. Cai, Y. Zhang, Z. Zhang, et al., “Super-resolution imaging of flat-mounted whole mouse cornea,” Exp. Eye Res. 205, 108499 (2021). [CrossRef]  

34. M. Bates, B. Huang, G. T. Dempsey, et al., “Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes,” Science 317(5845), 1749–1753 (2007). [CrossRef]  

35. M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3(10), 793–796 (2006). [CrossRef]  

36. E. Betzig, G. H. Patterson, R. Sougrat, et al., “Imaging Intracellular Fluorescent Proteins at Nanometer Resolution,” Science 313(5793), 1642–1645 (2006). [CrossRef]  

37. M. Dai, R. Jungmann, and P. Yin, “Optical imaging of individual biomolecules in densely packed clusters,” Nat. Nanotechnol. 11(9), 798–807 (2016). [CrossRef]  

38. X. Zhang, L. Beckmann, D. A. Miller, et al., “In Vivo Imaging of Schlemm's Canal and Limbal Vascular Network in Mouse Using Visible-Light OCT,” Invest. Ophthalmol. Visual Sci. 61(2), 23 (2020). [CrossRef]  

39. R. Fang, I. Rubinoff, and H. F. Zhang, “Multiple forward scattering reduces the measured scattering coefficient of whole blood in visible-light optical coherence tomography,” Biomed. Opt. Express 13(9), 4510–4527 (2022). [CrossRef]  

40. L. Beckmann, X. Zhang, N. A. Nadkarni, et al., “Longitudinal deep-brain imaging in mouse using visible-light optical coherence tomography through chronic microprism cranial window,” Biomed. Opt. Express 10(10), 5235–5250 (2019). [CrossRef]  

41. Q. Liu, S. Chen, B. Soetikno, et al., “Monitoring Acute Stroke in Mouse Model Using Laser Speckle Imaging-Guided Visible-Light Optical Coherence Tomography,” IEEE Trans. Biomed. Eng. 65(10), 2136–2142 (2018). [CrossRef]  

42. K.-H. Song, Y. Zhang, B. Brenner, et al., “Symmetrically dispersed spectroscopic single-molecule localization microscopy,” Light: Sci. Appl. 9(1), 92 (2020). [CrossRef]  

43. K.-H. Song, Y. Zhang, G. Wang, et al., “Three-dimensional biplane spectroscopic single-molecule localization microscopy,” Optica 6(6), 709–715 (2019). [CrossRef]  

44. M. Tokunaga, N. Imamoto, and K. Sakata-Sogawa, “Highly inclined thin illumination enables clear single-molecule imaging in cells,” Nat. Methods 5(2), 159–161 (2008). [CrossRef]  

45. M. Ovesný, P. Křížek, J. Borkovec, et al., “ThunderSTORM: a comprehensive ImageJ plug-in for PALM and STORM data analysis and super-resolution imaging,” Bioinformatics 30(16), 2389–2390 (2014). [CrossRef]  

46. L. Beckmann, Z. Cai, M. Margolis, et al., “Recent advances in optical coherence tomography for anterior segment imaging in small animals and their clinical implications,” Ocul. Surf. 26, 222–233 (2022). [CrossRef]  

47. G. D. Lively, B. Jiang, A. Hedberg-Buenz, et al., “Genetic Dependence of Central Corneal Thickness among Inbred Strains of Mice,” Invest. Ophthalmol. Visual Sci. 51(1), 160–171 (2010). [CrossRef]  

48. H. F. Edelhauser, “The Balance between Corneal Transparency and Edema The Proctor Lecture,” Invest. Ophthalmol. Visual Sci. 47(5), 1755–1767 (2006). [CrossRef]  

49. K. J. Mandell, G. P. Holley, C. A. Parkos, et al., “Antibody Blockade of Junctional Adhesion Molecule-A in Rabbit Corneal Endothelial Tight Junctions Produces Corneal Swelling,” Invest. Ophthalmol. Visual Sci. 47(6), 2408–2416 (2006). [CrossRef]  

50. B. Huang, S. A. Jones, B. Brandenburg, et al., “Whole-cell 3D STORM reveals interactions between cellular structures with nanometer-scale resolution,” Nat. Methods 5(12), 1047–1052 (2008). [CrossRef]  

51. R. K. P. Benninger and D. W. Piston, “Two-photon excitation microscopy for the study of living cells and tissues,” Curr. Protoc. Cell. Biol. 59, 4.11.1 (2013). [CrossRef]  

52. J. T. Lock, I. Parker, and I. F. Smith, “Communication of Ca2+ signals via tunneling membrane nanotubes is mediated by transmission of inositol trisphosphate through gap junctions,” Cell Calcium 60(4), 266–272 (2016). [CrossRef]  

53. H. R. Chinnery, E. Pearlman, and P. G. McMenamin, “Cutting Edge: Membrane Nanotubes In Vivo: A Feature of MHC Class II&l+ Cells in the Mouse Cornea,” J. Immunol. 180(9), 5779–5783 (2008). [CrossRef]  

54. S. McCutcheon, R. F. Stout, and D. C. Spray, “The dynamic Nexus: gap junctions control protein localization and mobility in distinct and surprising ways,” Sci. Rep. 10(1), 17011 (2020). [CrossRef]  

55. X. Sun, Y. Dai, Y. Chen, et al., “Primary angle closure glaucoma: What we know and what we don’t know,” Prog. Retinal Eye Res. 57, 26–45 (2017). [CrossRef]  

56. C. Y. Yang, Y. Liu, Z. Lu, et al., “Effects of Y27632 on aqueous humor outflow facility with changes in hydrodynamic pattern and morphology in human eyes,” Invest. Ophthalmol. Visual Sci. 54(8), 5859–5870 (2013). [CrossRef]  

Supplementary Material (1)

NameDescription
Supplement 1       Supplemental Info

Data Availability

Raw data presented in this paper is not yet publicly available but is available upon reasonable request.

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (5)

Fig. 1.
Fig. 1. Sample caption (Ref. [4], Fig. 2) The multiscale imaging workflow. (a) Illustration of a mouse eye; (b) A histological image of mouse cornea; (c) Comparing imaging resolution and penetration depth among OCT, CLSM, and SMLM; (d) An in-vivo vis-OCT B-scan image of a wild-type mouse cornea; (e) A 3D visualization using CLSM of a fixed mouse cornea flat-mount immunofluorescent labeled with a tight junction marker (ZO-1, red) and nuclear stain (DAPI, blue); (f) An CLSM image of the CEC tight junctions showing the classical hexagonal boundaries; (g) A magnified view of the area highlighted in panel e; (h) An SMLM image, with a similar FOV as the panel g, visualizing the nanoscale structures and filaments of the ZO-1 organizations between adjacent cells.
Fig. 2.
Fig. 2. Experimental protocol for generating mouse models of AOH and subsequent application of ROCK inhibitor.
Fig. 3.
Fig. 3. In vivo vis-OCT image of mouse cornea at four conditions. (a) Condition C1 with normal IOP and DMSO treatment; (b) Condition C2 with elevated IOP and DMSO treatment; (c) Condition C3 with normal IOP and Y-27623 treatment; (d) Condition C4 with elevated IOP and Y-27623 treatment; (e) Total corneal thickness variation; (f) Stromal thickness variation; (g) Corneal epithelium thickness variation; (h) Corneal endothelium thickness variation. N = 3 for each condition.
Fig. 4.
Fig. 4. Representative CLSM images of a cluster of CECs (a) Normal Type 1 ZO-1 structures; (b) Compact Type 2 ZO-1 structures; (c) Partially-distorted Type 3 ZO-1 structures; (d) Fully-distorted Type 4 ZO-1 structures; (e) Statistics of cell population exhibiting the four types of ZO-1 structures among 500-1500 cells from three mice; (f) Scatterplot of cell population measured from CLSM versus total corneal thickness measured from vis-OCT. Error bar: standard deviation; n = 4.
Fig. 5.
Fig. 5. SMLM images of (a) Type 1, (b) Type 2, (c) Type 3, and (d) Type 4 ZO-1 structures in CECs. The solid yellow lines in each panel illustrate the unambiguous thickness measurement of tight junction thickness using SMLM. The green and blue arrow-pointed areas indicate the classical tight junction discontinuities at three-cell Y-junctions and newly-discovered tight junction pores using SMLM. SEM images of CECs with (e) healthy tight junctions; (f) partially damaged tight junctions; (g) fully-distorted tight junctions. Yellow arrows point to tight junctions. (h) Tight junction widths measured from SMLM from the four types of CECs from the solid yellow lines. N = 5; (i) Line profiles of the stretched intercellular space ZO-1 nanofiber from the positions highlighted by the white dashed lines in panels d and g; the green scales indicate the ZO-1 fiber thickness measurement from the SEM image.

Tables (3)

Tables Icon

Table 1. In vivo thickness measurements by vis-OCT (± denotes standard deviations.)

Tables Icon

Table 2. Percentage population of the four types of ZO-1 structures in CECs imaged by CLSM.

Tables Icon

Table 3. SMLM measured widths of the four types of ZO-1 structures in CECs.