Filter Fluorometer Calibration Without the Fluorometer

Not Accessible

Your library or personal account may give you access

Abstract

We recently described a lightweight, low-power, waterproof filter fluorometer using a 180° backscatter geometry for chlorophyll-a (chl-a) detection. Before it was constructed it was modeled to ensure it would have satisfactory performance. This manuscript repeats the modeling process that allows the calibration slope and detection limit for a fluorescent analyte in water to be estimated from system component performance and conventional spectrofluorometry alone. These values are validated by comparison to the experimental result of calibration from the completed instrument. Our model yields a calibration slope of 8.22 mV-L/µg for dissolved chl-a, consistent with the experimentally measured slope of 8.21 mV-L/µg. The detection limit modeled from this slope and an estimate of the baseline noise of the instrument was 0.15 µg/L chl-a, while the measured detection limit using real blank samples was 0.18 µg/L, in 0.1 s differential measurements.

© 2023 The Author(s)

PDF Article
More Like This
Review of fluorescent standards for calibration of in situ fluorometers: Recommendations applied in coastal and ocean observing programs

Alan Earp, Christine E. Hanson, Peter J. Ralph, Vittorio E. Brando, Simon Allen, Mark Baird, Lesley Clementson, Paul Daniel, Arnold G. Dekker, Peter R.C.S. Fearns, John Parslow, Peter G. Strutton, Peter A. Thompson, Mark Underwood, Scarla Weeks, and Martina A. Doblin
Opt. Express 19(27) 26768-26782 (2011)

Calibration of an in-water multi-excitation fluorometer for the measurement of phytoplankton chlorophyll-a fluorescence quantum yield

Derek J. Griffith, Emma L. Bone, Sandy J. Thomalla, and Stewart Bernard
Opt. Express 26(15) 18863-18877 (2018)

Supplementary Material (1)

NameDescription
Supplement 1       sj-docx-1-asp-10.1177_00037028231181593 - Supplemental material for Filter Fluorometer Calibration Without the Fluorometer

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.