Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 77,
  • Issue 8,
  • pp. 819-834
  • (2023)

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Through a systematic scanning of 235U and 238U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF6) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235U–238U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U238U. The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235U–238U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235U enrichment of three UF6 samples of natural (0.720 atom% 235U) and low-enriched (4.675 atom% and 9.157 atom% 235U) grades. The U(I) 646.498 nm emission line, with a determined 235U–238U isotopic shift of −17.7 pm, was found to be the optimal spectral window for direct UF6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF6 samples, with each sample measured in six replicates, was 0.31% in absolute 235U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. The analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [235U/(235U + 238U)] ratios. Specific for the two low-enriched UF6 samples, the relative standard deviations from six replicated measurements were around 2%.

© 2022 The Author(s)

PDF Article
More Like This
Isotopic analysis by optogalvanic spectroscopy

P. Pianarosa, Y. Demers, and J. M. Gagné
J. Opt. Soc. Am. B 1(5) 704-709 (1984)

Comparative study of femtosecond and nanosecond laser-induced breakdown spectroscopy of depleted uranium

Luke A. Emmert, Rosemarie C. Chinni, David A. Cremers, C. Randy Jones, and Wolfgang Rudolph
Appl. Opt. 50(3) 313-317 (2011)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.