Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Active underwater detection with an array of atomic magnetometers

Open Access Open Access

Abstract

We report on a 2×2 array of radio-frequency atomic magnetometers in a magnetic induction tomography configuration. Active detection, localization, and real-time tracking of conductive, nonmagnetic targets are demonstrated in air and saline water. Penetration in different media and detection are achieved thanks to the sensitivity and tunability of the sensors, and to the active nature of magnetic induction probing. We obtained a 100% success rate for automatic detection and a 93% success rate for automatic localization in air and water, up to 190 mm away from the sensor plane (100 mm underwater). We anticipate magnetic induction tomography with arrays of atomic magnetometers finding applications in civil engineering and maintenance, the oil and gas industry, geological surveys, marine science, archeology, search and rescue, and security and surveillance.

Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

1. INTRODUCTION

Detection, localization, and tracking of remote or concealed objects is an open problem in many fields, particularly when penetration through absorbing or scattering media is required [16]. A critical case is underwater detection, where many conventional detection techniques are often ineffective [7]. For example, optical methods can be severely challenged [8], and acoustic systems incur increased difficulties at shallow depths [9,10]. In addition, the use of ionizing radiation or particles is often impractical or technically impossible because of the interaction (or the lack thereof) with media and targets.

Here, we present a proof-of-concept demonstration of detection and localization with an array of atomic magnetometers (AMs) [11] operating in a magnetic induction tomography (MIT) [12] configuration. This new approach does not suffer from the abovementioned limitations, and it is suitable for multipurpose use. Thanks to the sensitivity and tunability of AMs, MIT can be implemented with low fields and at low frequencies, thus matching the requirements for long-range penetration in media. In addition, the room temperature operation of AMs in unshielded environments, low running costs, miniaturization, scalability, and low costs for additional units make them an ideal solution for remote or underwater detection and localization [7].

We demonstrate active and automatic detection, localization, and tracking of conductive nonmagnetic targets in air and in saline water by continuously and simultaneously monitoring the output of a 2×2 planar array of AMs. We have obtained an overall success rate for detection of 100% in the explored configurations, and a 93% successful localization. Real-time tracking of moving targets is also demonstrated as well as multiple target simultaneous detection.

Although arrays of AMs have been previously realized (see, for example, [1315]), their operation in MIT modality has not. Our results demonstrate the feasibility of MIT with an array of AMs, and the relevance of such an instrument for the detection and localization of concealed targets. The technology can also be integrated with remote detection of rotating machinery with AMs [16] to create a multifunction sensing platform. This would provide a compact, safe, and active alternative for remote monitoring, surveying, and surveillance in many fields, as well as for increasing the throughput of MIT-AM imaging systems [17,18].

2. ARRAY OF RADIO-FREQUENCY ATOMIC MAGNETOMETERS

The setup is sketched in Fig. 1. Four radio-frequency (RF) AMs [1921], labeled as Sn, where n=1,,4, are arranged in a 2×2 planar configuration. Each sensor relies on Faraday rotation to detect the presence of a conductive target, where eddy currents are induced by an AC magnetic field orthogonal to the sensor plane. The output of each sensor (2 channels) is multiplexed in a DAQ board (NI USB-6009) and analyzed in real time via LabVIEW. Automatic control and variable thresholds (i.e., “decision levels”) are included for alarm triggering.

 figure: Fig. 1.

Fig. 1. Simplified sketch of the 2×2 RF AMs array for detection and localization. DBR: distributed Bragg reflector laser. DAVLL, dichroic atomic vapor laser lock; AOM, acousto-optic modulator; DAQ, data acquisition board; AMP, current amplifier; WF, waveform generator; REF IN, reference input; rn and ϕn are the amplitude and phase signals, respectively, of the nth sensor Sn.

Download Full Size | PDF

Detection is based on MIT. An AC primary magnetic field induces eddy currents in the target, which in turn generate a secondary field oscillating at the same frequency. A phase-sensitive detection scheme referenced to the primary field extracts the amplitude of the secondary field and its phase lag ϕ. The presence of a target is detected by measuring perturbations to the total magnetic field. This approach is inherently active: it triggers an unavoidable response in the target. The technique does not rely on intrinsic magnetic signatures and is therefore well suited for nonmagnetic or demagnetized targets. Furthermore, the electromagnetic near-field nature of the process also allows operation in shallow water, where acoustic-based systems are challenged.

In our setup, the primary field is produced by a square coil (RF coil) of side L=230mm (15 turns), placed in a parallel plane 45 mm above the sensor plane (Fig. 2). The coil is powered by a bipolar amplifier driven by a waveform generator.

 figure: Fig. 2.

Fig. 2. Arrangement for detection and localization. (a) The coordinate grid, parallel to the sensor plane. Each square is 77.5mm×77.5mm. (b) Arrangement of the sensors, RF coil, target, and saline water when applicable.

Download Full Size | PDF

The four RF AMs are based on a crossed pump/probe configuration, exciting the D2 line of R87b. The atomic vapor is contained in 25 mm cubic quartz cells, with 20 Torr of N2 as a buffer gas. A single semiconductor laser source at 780 nm generates four σ+ polarized probe beams (1 mW, beam waist 4 mm, 4.6Isat) tuned to the F=2F=3 transition. Circular Helmholtz coils (diameter 85 mm) provide a bias field for optical pumping for each Sn.

The MIT primary field acts as an RF drive for orthogonal components of the atomic polarization, by resonantly coupling adjacent Zeeman sublevels. This sets the atomic spins in precession (Larmor precession) at the frequency of the primary field. Such motion is detected through polarization rotation by four π-polarized probe beams (50 μW, beam waist 2.5 mm), detuned by +420MHz with respect to the “pump” transition. Faraday rotation is measured by four independent polarimeters whose output is selectively amplified by four dual-phase lock-in amplifiers. This allows simultaneous operation of the four sensors.

The secondary field produced by the target causes a change in the polarization rotation, and therefore a change in the amplitude rn and in the phase ϕn of the nth sensor’s output. In this way, the 2×2 array provides 8 streams of data for analysis.

The four sensors are arranged at the vertices of a square with a side of 105 mm. This distance and the mutual orientation allowed reduction of cross talk effects to a negligible value, as well as a satisfactory coverage of the experimental area. Each sensor has a sensitivity of 3nT/Hz at 10 kHz, measured with all four sensors in simultaneous operation. The sensors’ performance could be further improved by active compensation of stray magnetic fields [18]. Unlike previous realizations of MIT with RF AM single sensors [17,18,22], the targets are not enclosed between the sensor(s) and the RF coil. The entire sensing system lies below (or above) the object of interest. This has major advantages in view of practical applications, from screening [18] to biomedical imaging [23], as well as underground and underwater surveying.

3. ARRAY OPERATION: DETECTION AND LOCALIZATION OF CONDUCTIVE TARGETS

The penetration of an AC magnetic field in media is governed by the exponential decay B(z)=B(z=0)exp(z/δ(ν)), where the skin depth δ(ν) is:

δ(ν)=12πνμϵ2(1+(σ2πϵν)21).
Here, ν is the AC field’s frequency, ϵ is the permittivity, μ is the permeability, and σ is the electric conductivity of the medium. According to Eq. (1), low frequencies are required for long-range penetration and hence remote detection. In this regime, AMs outperform conventional sensors [7,24]. A primary field frequency of between 10 kHz and 20 kHz is chosen for this work. This allows sufficient penetration of the MIT fields in media and targets, with negligible attenuation in air (σair1015S/m [25]): penetration exceeding 108km can be obtained, in principle. This range is significantly reduced in sea water, as discussed in Section 4.A. We recall that MIT operation of RF AM in a band as low as 102Hz has been recently reported [18]. With this choice of frequencies and distances between the sensor array and the target, the electromagnetic interaction is limited to the near-field regime. This corresponds to the quasi-static limit of electromagnetism, described by diffusion equations, rather than to the familiar wave propagation regime of far-field electromagnetism.

To demonstrate the operation of the array and the limited impact of cross talk, the response of the four sensors is measured as a function of the target’s position. Figure 3 shows the variation in the amplitude of the four Sn when an Al plate (105mm×110mm×10mm) is placed on the nine positions (i,j). Δr=|rtargetrbg| (where rtarget,bg indicate the amplitude of the Faraday rotation signal with and without the target, respectively) is plotted as a function of target’s position.

 figure: Fig. 3.

Fig. 3. Response of the nth sensor (Sn (in,jn)): Δr produced by an Al plate (105mm×110mm×10mm) in air 90 mm above the sensor plane, detected at 20 kHz. The plate is placed in each of the 9 grid positions and the corresponding Δr is independently recorded with each sensor. Different responses may be observed due to the independent optimization of each sensor in the array.

Download Full Size | PDF

A systematic increase of Δr is observed when the target is in proximity of the sensor. Given the experimental arrangement [Fig. 2(b)], direct screening of the primary field by the target is excluded. This behavior is consistent with MIT detection: the secondary field excited in the target perturbs the RF-driven Faraday rotation in the array. The effect is larger when the target is closer to the sensor, where the secondary field is stronger: up to 10 times larger than the neighboring values. Furthermore, a systematic decrease of the signal from all sensors is observed when the object is in the center of the grid (2,2). This allows unambiguous localization of the target in five different positions. The four vertices of the coordinate grid are not taken into consideration.

This is demonstrated in Fig. 4. Δr is simultaneously measured by the four Sn when the Al plate is placed in different positions, 90 mm above the sensor plane. The LabVIEW control displays the measured values in real time and compares them to the corresponding background. An alarm showing the target’s position on the grid is automatically triggered upon detection (see also Visualization 1 [26]).

 figure: Fig. 4.

Fig. 4. Target localization: simultaneously recorded Δr, when an Al plate (105mm×110mm×10mm), in air 90 mm above the sensor plane, is placed in different positions. Operation frequency: 20 kHz.

Download Full Size | PDF

Clear signatures of the target’s presence and position are confirmed, with negligible cross talk among Sn. We attribute the small variations observed in some cases to random fluctuations (10% in the response of the same sensor in the same conditions, over several days, in the case of the smallest tested target sized 44mm×50mm×13mm). However, these do not hamper the detection and localization of the target: we obtained 100% correct automatic detections and localizations with the Al plate.

The phase variation Δϕn=ϕtargetϕbg is also recorded. A decrease is observed when the object is above a sensor, leading to unambiguous detection and correct localization. After detailed analysis, we found Δϕ to be a less robust parameter than Δr. We attribute this to the larger intrinsic variability of the phase data. Therefore, Δϕ is not taken into further consideration in this work.

Figure 5 shows the results of a similar experiment, conducted with an Al block of 44mm×50mm×13mm in air, 90 mm above the sensor plane. A five-fold decrease of the signal is observed. This is due to the smaller size of the target: the 5× decrease in Δr is consistent with the ratio of the two targets’ areas, 5.25 [27].

 figure: Fig. 5.

Fig. 5. Target localization: simultaneously recorded Δr, when an Al target (44mm×50mm×13mm) in air, 90 mm above the sensor plane, is placed in different positions. Operation frequency: 20 kHz.

Download Full Size | PDF

Nevertheless, clear detection and effective localization are demonstrated. Overall, a correct localization rate of 95.2% over 21 sets of tests was obtained at 20 kHz.

4. UNDERWATER DETECTION AND LOCALIZATION

A. Saline Water Test Bed

To test the array with underwater detection and localization, we used a test bed mimicking the worst-case scenario of sea water. A 25 mm thick Perspex platform above the main coil supports a nylon water tank (355mm×215mm×265mm). The target is immersed in the water and held at different depths. The sensor plane and the water level are separated by 90 mm containing air and two layers of plastic, which mimics the realistic scenario of a sensing platform above water on a supporting structure and an underwater target.

To reproduce the average electric conductivity of sea water, we used a 0.0231 NaCl solution with deionized water. Deionized water allows detailed control of the solution conductivity. A NaCl/water solution with a salinity of 22.1 matches the sea conditions at 22°C: ϵsea=ϵ0ϵr,sea=8.854·1012·80F/m, μ=μ0μr,sea=1.26·106·1H/m, σ=3.3S/m [28,29].

In the band chosen for this work (10 to 20 kHz), the skin depth in sea water varies between 2.8 m and 1.9 m. Penetration of a km can be achieved by further reducing the RF frequency (Eq. 1).

B. Underwater Experimental Results

In this section, we demonstrate the detection and localization of underwater nonmagnetic targets.

In Fig. 6, the Al plate is placed 30 mm under water, 120 mm above the array’s plane.

 figure: Fig. 6.

Fig. 6. Underwater target detection and localization: simultaneously recorded Δr, when an Al plate (105mm×110mm×10mm) is placed in different positions, at 30 mm underwater (120 mm from the array plane). Operation frequency: 10 kHz.

Download Full Size | PDF

The absolute levels of the amplitude signals decrease. We measured Δr8 times smaller than Fig. 4. This value reduces to a factor 3 in the case of the central (2, 2) position. Nevertheless, the array measures consistent variations in the presence of the target, and unambiguous detection and localization are achieved.

Overall, excellent performance for automatic localization is obtained: over 22 separate tests at different depths, the success rate was 91%. This number increases to 95% for depths smaller than 50 mm (140mm above the array plane). At deeper locations, the success rate progressively decreases: at 65 mm deep, automatic localization is successful in 70% of cases. No correlations were found between the position and the failure rate.

Underwater depth and distance from the RF coil play a relevant role, as demonstrated by Fig. 7. In the graph, S2 Δr is plotted versus the depth underwater and the distance from the sensor plane of a thin Al plate (105mm×73mm×3mm) in position (2, 3).

 figure: Fig. 7.

Fig. 7. Underwater target detection: Δr of S2 as a function of the depth of the target, a thin Al plate (105mm×73mm×3mm), detected at 10 kHz, placed in position (2,3), above the sensor. The dashed horizontal line marks the “zero-level” compatible with no possible detection, corresponding to 100 mm underwater (190 mm distance from the sensor plane).

Download Full Size | PDF

Water attenuates both the primary and the secondary fields, producing a noticeable decrease of the MIT signal. Such variation is estimated of the order of 10%. Therefore, water attenuation alone cannot account for the observed decrease in Δr. These results could be improved by optimizing the design of the RF source, or by using better approaches for automatic localization, such as machine learning [30]. Increasing the number of sensors will also improve the localization and tracking performance. We recall that detection and localization in shallow water—where acoustic methods are overwhelmed by echoes and optical methods are hampered by opacity and turbulence of water—is of primary importance for many fields, including surveillance, industrial monitoring, and surveying.

Finally, by using the LabVIEW automatic real-time detection interface, demonstrations of: (i) detection and localization of multiple targets; (ii) suppression of background structures or targets; and (iii) live tracking of moving targets were achieved, as shown in Visualization 1 [26]. These features are essential prerequisites for the proposed applications, particularly surveillance. The active nature of the MIT approach makes conventional passive countermeasures such as magnetic degaussing [31] or acoustic cloaking [32] ineffective. We also note that, given the broad tunability of AMs, the primary field source frequency can be easily tuned for achieving different penetrations as well as avoiding noisy bands or concealing the active probing.

5. CONCLUSIONS

We have demonstrated detection and localization of conductive, nonmagnetic targets by using a 2×2 planar array of radio-frequency atomic magnetometers operating in a magnetic induction tomography configuration. The sensors in the array are operated continuously and simultaneously with negligible cross talk. The active nature of the magnetic induction detection, combined with the sensitivity and tunability of RF AMs, makes this approach suitable for operation in unshielded environments and achieving long penetration ranges to detect fixed and moving targets.

A proof-of-concept demonstration in saline water proved the feasibility of an MIT-based array of AMs for underwater detection and tracking, also in shallow water where other conventional approaches have limited effectiveness.

Our results lay the groundwork for potential applications from archeological surveys to civil engineering. We found no evidence to suggest fundamental limitations in scaling up the array or increasing the monitored area. Furthermore, integrating the active tracking demonstrated here with passive detection of the AC electromagnetic signatures of motors [16] could provide a novel class of early surveillance platforms suitable for land, air, and water applications.

Funding

UK Quantum Technology Hub in Sensing and Metrology, Engineering and Physical Sciences Research Council (EPSRC) (EP/M013294/1; EP/L015242/1).

Acknowledgment

Cameron Deans acknowledges support by the EPSRC.

REFERENCES AND NOTES

1. M. R. Yenchek, G. T. Homce, N. W. Damiano, and J. R. Srednicki, “NIOSH-sponsored research in through-the-earth communications for mines: Astatus report,” IEEE Trans. Ind. Appl. 48, 1700–1707 (2012). [CrossRef]  

2. B. Lord, “Remote sensing techniques for onshore oil and gas exploration,” Lead Edge 36, 24–32 (2017). [CrossRef]  

3. R. Lasaponara and N. Masini, Satellite Remote Sensing: A New Tool for Archaeology (Springer, 2014), Vol. 16.

4. M. T. Eismann, A. D. Stocker, and N. M. Nasrabadi, “Automated hyperspectral cueing for civilian search and rescue,” Proc. IEEE 97, 1031–1055 (2009). [CrossRef]  

5. A. Oracevic, S. Akbaş, S. Ozdemir, and M. Kos, “Secure target detection and tracking in mission critical wireless sensor networks,” in International Conference on Anti-Counterfeiting, Security and Identification (ASID) (2014), pp. 1–5.

6. G. Pajares, “Overview and current status of remote sensing applications based on unmanned aerial vehicles (UAVS),” Photogramm. Eng. Remote Sens. 81, 281–330 (2015). [CrossRef]  

7. V. Gerginov, F. C. S. da Silva, and D. Howe, “Prospects for magnetic field communications and location using quantum sensors,” Rev. Sci. Instrum. 88, 125005 (2017). [CrossRef]  

8. R. Schettini and S. Corchs, “Underwater image processing: State of the art of restoration and image enhancement methods,” EURASIP J. Applied Signal Processing 2010, 746052 (2010). [CrossRef]  

9. H. Bucker, “Matched-field tracking in shallow water,” J. Acoust. Soc. Am. 96, 3809–3811 (1994). [CrossRef]  

10. D. A. Abraham and P. K. Willett, “Active sonar detection in shallow water using the page test,” IEEE J. Ocean. Eng. 27, 35–46 (2002). [CrossRef]  

11. D. Budker and M. Romalis, “Optical magnetometry,” Nat. Phys. 3, 227–234 (2007). [CrossRef]  

12. H. Griffiths, “Magnetic induction tomography,” Meas. Sci. Technol. 12, 1126–1131 (2001). [CrossRef]  

13. P. Knowles, G. Bison, N. Castagna, A. Hofer, A. Mtchedlishvili, A. Pazgalev, and A. Weis, “Laser-driven Cs magnetometer arrays for magnetic field measurement and control,” Nucl. Instrum. Methods Phys. Res. Sect. A 611, 306–309 (2009). Particle Physics with Slow Neutrons. [CrossRef]  

14. R. Wyllie, M. Kauer, R. T. Wakai, and T. G. Walker, “Optical magnetometer array for fetal magnetocardiography,” Opt. Lett. 37, 2247–2249 (2012). [CrossRef]  

15. R. J. Cooper, D. W. Prescott, P. Matz, K. L. Sauer, N. Dural, M. V. Romalis, E. L. Foley, T. W. Kornack, M. Monti, and J. Okamitsu, “Atomic magnetometer multisensor array for rf interference mitigation and unshielded detection of nuclear quadrupole resonance,” Phys. Rev. Appl. 6, 064014 (2016). [CrossRef]  

16. L. Marmugi, L. Gori, S. Hussain, C. Deans, and F. Renzoni, “Remote detection of rotating machinery with a portable atomic magnetometer,” Appl. Opt. 56, 743–749 (2017). [CrossRef]  

17. C. Deans, L. Marmugi, S. Hussain, and F. Renzoni, “Electromagnetic induction imaging with a radio-frequency atomic magnetometer,” Appl. Phys. Lett. 108, 103503 (2016). [CrossRef]  

18. C. Deans, L. Marmugi, and F. Renzoni, “Through-barrier electromagnetic imaging with an atomic magnetometer,” Opt. Express 25, 17911–17917 (2017). [CrossRef]  

19. I. M. Savukov, S. J. Seltzer, M. V. Romalis, and K. L. Sauer, “Tunable atomic magnetometer for detection of radio-frequency magnetic fields,” Phys. Rev. Lett. 95, 063004 (2005). [CrossRef]  

20. M. P. Ledbetter, V. M. Acosta, S. M. Rochester, D. Budker, S. Pustelny, and V. V. Yashchuk, “Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation,” Phys. Rev. A 75, 023405 (2007). [CrossRef]  

21. W. Chalupczak, R. M. Godun, S. Pustelny, and W. Gawlik, “Room temperature femtotesla radio-frequency atomic magnetometer,” Appl. Phys. Lett. 100, 242401 (2012). [CrossRef]  

22. A. Wickenbrock, N. Leefer, J. W. Blanchard, and D. Budker, “Eddy current imaging with an atomic radio-frequency magnetometer,” Appl. Phys. Lett. 108, 183507 (2016). [CrossRef]  

23. L. Marmugi and F. Renzoni, “Optical magnetic induction tomography of the heart,” Sci. Rep. 6, 23962 (2016). [CrossRef]  

24. I. Savukov, S. Seltzer, and M. Romalis, “Detection of NMR signals with a radio-frequency atomic magnetometer,” J. Magn. Reson. 185, 214–220 (2007). [CrossRef]  

25. S. D. Pawar, P. Murugavel, and D. M. Lal, “Effect of relative humidity and sea level pressure on electrical conductivity of air over Indian ocean,” J. Geophys. Res. 114, D02205 (2009).

26. C. Deans, L. Marmugi, and F. Renzoni, “Video demonstration of active detection with an array of atomic magnetometers,” https://doi.org/10.6084/m9.figshare.5674795 (2017). [Online; 12-November-2017].

27. At 20 kHz, δAl=0.58mm, which is much smaller than the thickness of both targets. Consequently, the relevant parameter for eddy current in this case is only the surface enclosing the magnetic flux changes. This corresponds, for each of the two targets, to their areas.

28. W. Ellison, A. Balana, G. Delbos, K. Lamkaouchi, L. Eymard, C. Guillou, and C. Prigent, “New permittivity measurements of seawater,” Radio Sci. 33, 639–648 (1998). [CrossRef]  

29. G. Benelli and A. Pozzebon, “RFID under water: Technical issues and applications,” in Radio Frequency Identification from System to Applications, M. B. I. Reaz, ed. (InTech, 2013), Chap. 18.

30. C. Deans, L. D. Griffin, L. Marmugi, and F. Renzoni, “Machine learning based localization and classification with atomic magnetometers,” Phys. Rev. Lett. 120, 033204 (2018). [CrossRef]  

31. J. T. Kephart, B. K. Fitzpatrick, P. Ferrara, M. Pyryt, J. Pienkos, and E. M. Golda, “High temperature superconducting degaussing from feasibility study to fleet adoption,” IEEE Trans. Appl. Supercond. 21, 2229–2232 (2011). [CrossRef]  

32. H. Chen and C. T. Chan, “Acoustic cloaking in three dimensions using acoustic metamaterials,” Appl. Phys. Lett. 91, 183518 (2007). [CrossRef]  

Supplementary Material (1)

NameDescription
Visualization 1       Demonstration of active detection with an array of atomic magnetometers.

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (7)

Fig. 1.
Fig. 1. Simplified sketch of the 2 × 2 RF AMs array for detection and localization. DBR: distributed Bragg reflector laser. DAVLL, dichroic atomic vapor laser lock; AOM, acousto-optic modulator; DAQ, data acquisition board; AMP, current amplifier; WF, waveform generator; REF IN, reference input; r n and ϕ n are the amplitude and phase signals, respectively, of the n th sensor Sn.
Fig. 2.
Fig. 2. Arrangement for detection and localization. (a) The coordinate grid, parallel to the sensor plane. Each square is 77.5 mm × 77.5 mm . (b) Arrangement of the sensors, RF coil, target, and saline water when applicable.
Fig. 3.
Fig. 3. Response of the n th sensor (Sn ( i n , j n )): Δ r produced by an Al plate ( 105 mm × 110 mm × 10 mm ) in air 90 mm above the sensor plane, detected at 20 kHz. The plate is placed in each of the 9 grid positions and the corresponding Δ r is independently recorded with each sensor. Different responses may be observed due to the independent optimization of each sensor in the array.
Fig. 4.
Fig. 4. Target localization: simultaneously recorded Δ r , when an Al plate ( 105 mm × 110 mm × 10 mm ), in air 90 mm above the sensor plane, is placed in different positions. Operation frequency: 20 kHz.
Fig. 5.
Fig. 5. Target localization: simultaneously recorded Δ r , when an Al target ( 44 mm × 50 mm × 13 mm ) in air, 90 mm above the sensor plane, is placed in different positions. Operation frequency: 20 kHz.
Fig. 6.
Fig. 6. Underwater target detection and localization: simultaneously recorded Δ r , when an Al plate ( 105 mm × 110 mm × 10 mm ) is placed in different positions, at 30 mm underwater (120 mm from the array plane). Operation frequency: 10 kHz.
Fig. 7.
Fig. 7. Underwater target detection: Δ r of S2 as a function of the depth of the target, a thin Al plate ( 105 mm × 73 mm × 3 mm ), detected at 10 kHz, placed in position (2,3), above the sensor. The dashed horizontal line marks the “zero-level” compatible with no possible detection, corresponding to 100 mm underwater (190 mm distance from the sensor plane).

Equations (1)

Equations on this page are rendered with MathJax. Learn more.

δ ( ν ) = 1 2 π ν μ ϵ 2 ( 1 + ( σ 2 π ϵ ν ) 2 1 ) .
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.