Abstract
In the context of the Large Binocular Telescope project, we present the results of force actuator calibrations performed on an adaptive secondary prototype called P45, a thin deformable glass with magnets glued onto its back. Electromagnetic actuators, controlled in a closed loop with a system of internal metrology based on capacitive sensors, continuously deform its shape to correct the distortions of the wavefront. Calibrations of the force actuators are needed because of the differences between driven forces and measured forces. We describe the calibration procedures and the results, obtained with errors of less than 1.5%.
© 2008 Optical Society of America
Full Article | PDF ArticleMore Like This
Guido Brusa and Ciro Del Vecchio
Appl. Opt. 37(21) 4656-4662 (1998)
David Alaluf, Renaud Bastaits, Kainan Wang, Mihaita Horodinca, Grégory Martic, Bilal Mokrani, and André Preumont
Appl. Opt. 57(14) 3629-3638 (2018)
Simone Esposito, Armando Riccardi, Fernando Quirós-Pacheco, Enrico Pinna, Alfio Puglisi, Marco Xompero, Runa Briguglio, Lorenzo Busoni, Luca Fini, Paolo Stefanini, Guido Brusa, Andrea Tozzi, Piero Ranfagni, Francesca Pieralli, Juan C. Guerra, Carmelo Arcidiacono, and Piero Salinari